ADM-M land call modul
Technicaldata
8
ADMmanual
4
ADM-M land call modul
The ADM-M land call modul forms the interface between the landing call panel and FST control system. The
ADM-M is connected to the FST via the LON bus.
The ADM-3 is typically installed on each floor.
This module combines the previous modules ADM-S and ADM-D.
Characteristics of the new hardware are:
›Micro-Match plug for plug & play connection of control- (Call UP/DOWN) and display elements (UP/DOWN/
›Occupied)
›sunken yellow Service-LED
›Service-Pin as contact area
›sunken red LED between X1 and X2
›sunken green LED between X1 and X2
›micro fuse 250 mA between X1 and X2
›additional connection of key switch, acoustic click etc. on the terminal strip X6
The ADM-M is either installed and pre-wired in the landing call panel or delivered loose (to be installed in the
shaft).
4.1
Technical data
Description
Value
Supply voltage
24 V DC ±10%
Typical power consumption
50 mA
Outputs
Short circuit-proof
Length x height x depth
50 x 54 x 20 mm
Temperature range: Storage & transport / operation
-20 – +70 °C / ±0 – +60 °C
Relative humidity: Storage & transport / operation
(non-condensing)
+5 – +95 % / +15 – +85 %
X1
X2
J1
X6
250 mA
Service
52
48
24
3,5
3,5
X3
X8
X
X7
X5
X9
X4
Fig. 4.1: ADM-M circuit board marking