- 129 -
NL345
www.NewLeader.com
(800) 363-1771
312884-AA-C
Hydraulic Alarms
Alarm
Description
Trigger
Conveyor
Hydraulic
Pressure Exceeds
Maximum
“Conveyor Hydraulic Pressure Exceeds
Maximum Operating Range�”
Conveyor hydraulic pressure exceeds
[Max Conveyor Hydraulics Pressure]
setting for a period of five consecutive
seconds or longer�
System Hydraulic
Pressure Exceeds
Maximum
“System Hydraulic Pressure Exceeds
Maximum Operating Range�”
System hydraulic pressure exceeds [Max
System Hydraulics Pressure] setting for
a period of five consecutive seconds or
longer�
Hydraulic Fluid
Level Low
“Hydraulic Fluid Level Low�”
Hydraulic fluid level has fallen below
lowest level tank sensor�
Hydraulic Fluid
Temperature
Below Minimum
“Hydraulic Fluid Temperature Below
Minimum Operating Range�”
Hydraulic temperature is below 65°F
(18°C). Hydraulic fluid too cold to
operate machine�
Hydraulic Fluid
Temperature
Exceeds
Maximum
“Hydraulic Fluid Temperature Exceeds
Maximum Operating Range�”
Hydraulic temperature exceeds
maximum operating range, greater than
or equal to 200°F (93°C)�
Hydraulic Filter
Restriction
Detected
“Hydraulic Filter Restriction Detected�”
Hydraulic filter pressure is greater than
or equal to 25 psi for five consecutive
seconds or longer�
Bin Sequencing Alarms
Alarm
Description
Trigger
Container
Advance
Moving to next container in the
sequence�
At the point when the [Container
Advance] criteria has been met�
End of Sequence
End of container sequence, do you
wish to start the sequence from the
beginning?
At the point the last container in the
sequence has met the [Container
Advance] criteria�
Chain Oiler Alarms
Alarm
Description
Trigger
Disable Spinners
Manually disable or shut off the spinner
hydraulic circuit�
The point the user selects to run the
chain oiler routine�
Enable Spinners
Return the spinner hydraulic circuit to a
field ready condition.
The point the user exits the chain oiler
routine�
Conveyor
Lubrication
Required
Conveyor Chain Lubrication Is Required�
[Service Reminder On] setting is enabled
and [Service Reminder Interval] has
expired�
Controller Operations
Содержание NL345/MULTAPPLIER
Страница 6: ...Insert Current New Leader Warranty Warranty...
Страница 23: ...23 NL345 www NewLeader com 800 363 1771 312884 AA C This page is intentionally left blank Notes...
Страница 24: ...24 www NewLeader com 800 363 1771 312884 AA C NL345 7 6 6 5 2 2 1 1 3 3 4 4 1 1 TR3000 Safety Decals...
Страница 26: ...26 www NewLeader com 800 363 1771 312884 AA C NL345 Informational Decals 1 1...
Страница 28: ...28 This page is intentionally left blank www NewLeader com 800 363 1771 312884 AA C NL345 Notes...
Страница 51: ...51 This page is intentionally left blank NL345 www NewLeader com 800 363 1771 312884 AA C Notes...
Страница 58: ...58 This page is intentionally left blank www NewLeader com 800 363 1771 312884 AA C NL345 Notes...
Страница 68: ...68 www NewLeader com 800 363 1771 312884 AA C NL345 This page is intentionally left blank Notes...
Страница 74: ...74 www NewLeader com 800 363 1771 312884 AA C NL345 SPREADER TR3000 MULTAPPLIER Serial Number Locations...
Страница 86: ...86 www NewLeader com 800 363 1771 312884 AA C NL345 Header Hydraulic Schematic TR3000 Brakes...
Страница 114: ...114 www NewLeader com 800 363 1771 312884 AA C NL345 Notes This Page Intentionally Left Blank...
Страница 132: ...132 This page is intentionally left blank www NewLeader com 800 363 1771 312884 AA C NL345 Notes Notes...