General Product Control Alarms
Alarm
Description
Trigger
Rate sensor error
during calibration
“Calibration error, lost or intermittent
signal from rate sensor� Check sensor
and related wiring prior to calibrating
conveyor�”
Rate sensor signal is lost for a period
of two or more consecutive seconds
during the Static Conveyor Calibration
Routine�
Rate Sensor Error
During Conveyor
Flush
"Lost or intermittent signal from rate
sensor� Check sensor and related wiring
prior to continuing Conveyor Flush
Routine�"
Rate sensor signal is lost for a period
of two or more consecutive seconds
during the Conveyor Flush Routine�
Low Bin Sensor
"Low Bin Sensor�" [Channel Name]�
Bin Level Sensor is installed, metering
circuit is commanded on, and the
product in the bin does not cover
the sensor for a consecutive period
of time greater than current [Low Bin
Time Delay] setting�
Disable Spinners
"Manually disable or shut off the spinner
hydraulic circuit�"
At the beginning of the Static
Conveyor Calibration and Conveyor
flush routine.
Enable Spinners
"Return the spinner hydraulic control to a
field ready condition. The spinners will now
restart�"
At the end of the Static Conveyor
Calibration routine and Conveyor flush
routine�
Boundary
Spinner Not
Responding
"Boundary Spinner Not Responding�" +
[Spinner Name]�
Automatic control for spinners must
be enabled� At least one conveyor
must be commanded on� Perceived
spinner speed is greater than 30RPM
in error from the [Boundary Spreading
Spinner RPM Offset]�
Rate Not
Responding
“Rate Not Responding” + [Channel
Name]�
Control channel is commanded
on using automatic control mode�
Application rate is +/- [Rate Not
Responding Threshold] from target
rate for a period of [Rate Not
Responding Timeout] or more�
Maximum
Conveyor Speed
“Conveyor At Maximum RPM, Slow Down”
+ [Channel Name]�
Product channel is commanded
on and conveyor is run at or above
maximum speed for a period of 5 or
more consecutive seconds�
Minimum
Conveyor Speed
“Conveyor At Minimum RPM”, + [Channel
Name]�
Product channel is commanded
on and conveyor is run at or below
minimum speed for a period of 5 or
more consecutive seconds�
Conveyor Not
Responding
“Conveyor Running While Turned Off” +
[Channel Name]�
Product bin is commanded off and
conveyor speed >0 and <1 RPM for
a period of 30 or more consecutive
seconds� Or conveyor speed is
>=1 RPM for a period of 5 or more
consecutive seconds�
Controller Operations
Содержание NL345/MULTAPPLIER
Страница 6: ...Insert Current New Leader Warranty Warranty...
Страница 23: ...23 NL345 www NewLeader com 800 363 1771 312884 AA C This page is intentionally left blank Notes...
Страница 24: ...24 www NewLeader com 800 363 1771 312884 AA C NL345 7 6 6 5 2 2 1 1 3 3 4 4 1 1 TR3000 Safety Decals...
Страница 26: ...26 www NewLeader com 800 363 1771 312884 AA C NL345 Informational Decals 1 1...
Страница 28: ...28 This page is intentionally left blank www NewLeader com 800 363 1771 312884 AA C NL345 Notes...
Страница 51: ...51 This page is intentionally left blank NL345 www NewLeader com 800 363 1771 312884 AA C Notes...
Страница 58: ...58 This page is intentionally left blank www NewLeader com 800 363 1771 312884 AA C NL345 Notes...
Страница 68: ...68 www NewLeader com 800 363 1771 312884 AA C NL345 This page is intentionally left blank Notes...
Страница 74: ...74 www NewLeader com 800 363 1771 312884 AA C NL345 SPREADER TR3000 MULTAPPLIER Serial Number Locations...
Страница 86: ...86 www NewLeader com 800 363 1771 312884 AA C NL345 Header Hydraulic Schematic TR3000 Brakes...
Страница 114: ...114 www NewLeader com 800 363 1771 312884 AA C NL345 Notes This Page Intentionally Left Blank...
Страница 132: ...132 This page is intentionally left blank www NewLeader com 800 363 1771 312884 AA C NL345 Notes Notes...