(2).Installed in the following locations may cause the machine to malfunction.
◆
Places such as cutting oil and other mineral oils.
◆
Places with salted air near the sea.
◆
Places which contains gas such as sulfur, acidic or alkaline and other corrosive gases
in the spa area.
◆
The place is with seriously voltage fluctuations and have strong electromagnetic waves.
◆
Kitchen and other places which are full of oil odor, and oil trace.
(3).Unit infrastructure installation
Units can be installed base of concrete structures, and steel brackets can also be used to
install, basic surface is roughness (basic is designed according to the operational quality and
according to the technical performance parameters table). Under the unit, should install the
vibration damping rubber, and fix with bolts. Adjust the unit installation level, tilt <2 degrees.
On the ground should have the drains for unit's condensate.
Notice:
When installing circulating pump outside of the unit, the warm water pipes use
which according to the heat pump’s specification, all pipes should do thermal
insulation. The unit is suitable for single-floor, if for multi-layer use, it must install
circulation pump outside and confirmed by the distributor.