20
P29
reserve
P30
Antifreeze switch
0,1
0
0=Invalid
1=valid
P31
Model parameter selection
0~7
7
6. Unit fault code table
Fault code
No.
Fault Name
E01
Outdoor unit current protection
E02
Flow switch protection
E03
EEPROM error indication (indoor board) / EEPROM error indication
(operation panel)
E04
Return water temperature over high when heating or output water
temperature over low when cooling
E05
DC link voltage is over high / low protection
E06
IPM failure
E08
Output and input water temperature different too large protection
E09
Communication error ( indoor board and outdoor board)
E10
Return water temp sensor fault
E11
Output water temp sensor fault
E12
Tank temp sensor fault
E13
Ambient temp sensor fault
E14
Evaporator temp sensor fault
E18
Compressor outlet gas temp sensor fault
E21
Compressor outlet gas temperature over high
E25
Evaporator coil temperature too high when cooling model
E31
System pressure over high protection
E32
Communication error (operation panel & indoor board)
E33
Communication error (IPM & outdoor board)
E41
System pressure over low protection
E44
Winter unit standby antifreeze protection
E45
Return gas temp sensor fault
E46
Temp sensor fault after throttle
E47
Water tank temperature sensor abnormal protection
E48
Antifreeze switch disconnect failure