USAGE:
Make sure the space to be treated is free of people, pets, and plants. Place the unit on top of a sturdy, elevated
surface ideally 3-5 feet off the ground. Seal the treatment area to avoid ozone leakage to nearby areas.
CAUTION:
NEVER PLUG UNIT INTO A POWER STRIP. PLUG INTO A WALL OUTLET ONLY
Ozone in high concentrations is a lung irritant.
Ozone generators should only be used in unoccupied spaces, free of people, pets, and plants.
Do not look directly at UV light for prolonged amount of time, may cause eye irritation.
To operate the ozone generator:
1. Connect the power adaptor to the unit and an active, grounded power outlet.
2. Set the timer according to the area size and time table below.
3. The generator will automatically turn off after the timer has finished.
4. To choose the Interval function, press once, the unit will work in 12 hour interval; press twice, it will work in 24 hour interval;
press three times to cancel the interval work.
5. Allow 40 minutes for the space to air out before re-entering the treated space.
6. If necessary, ozone treatment can be repeated according to the time table below.
Application Areas and Time Table ( 100% ozone output
APPLICATION AREA
TREATMENT TIME
APPLICATION AREA
TREATMENT TIME
400
ft
2
15 mins
3,200
ft
2
120 mins
1,200
ft
2
45 mins
4,000
ft
2
150 mins
1,600
ft
2
60 mins
4,800
ft
2
180 mins
2,400
ft
2
90 mins
6,400
ft
2
240 mins