LIGHTING INSTRUCTIONS
1.
STOP!
Read the safety information on page 19.
2. Make sure manual shutoff valve is fully open.
3. Turn off all electrical power to the appliance. Open access door.
4. Turn control knob clockwise
¬
to the “OFF” position.
Figure
16
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near
the floor. If you smell gas, STOP and follow “B” in the safety information on
page 19! If you don’t smell gas, go to the next step.
Figure
17
6. Turn control knob counterclockwise
«
to the “PILOT” position. Press in
control knob for fifteen (15) seconds.
NOTE:
You may be running this heater for the first time after hooking up the
gas supply. If so, the control knob may need to be pressed in for thirty (30)
seconds. This will allow air to bleed from the gas system.
7. With control knob pressed in, push down and release ignitor button. This will
light the pilot. If needed, keep repeating this step until pilot lights. If pilot does
not light with piezo, light by hand with a match.
8. Keep control knob pressed in for one (1) minute after lighting pilot. After
one (1) minute, release control knob.
* If knob does not pop up when released, stop and immediately call your service
technician or gas supplier.
*If the pilot will not stay lit after several tries, turn the gas control knob to the
“OFF” position and call your service technician or gas supplier.
NOTE: Pilot is located between
the first and second burner.
OU
T
L
T
O
I P
IN
OU
T
L
T
O
I P
IN
CONTROL KNOB
20
Содержание DV23ZC
Страница 2: ......
Страница 4: ...2...
Страница 8: ...INSTALLATION Figure 1 6...
Страница 30: ...REPLACEMENT PARTS Figure 22 16 28...