Nevco MPCX 1000 Скачать руководство пользователя страница 21

17 

ON/

OFF 

This menu option reports the number of receivers the control is 
currently linked to (

0

/0), and the number of receivers on its 

“Link To” list (0/

0

). The option also allows you to link a control 

to a scoreboard (receiver) or group of scoreboards (receivers). 
This link procedure is required only at the time of installation, 
when additional controls are added to an existing system, a 
change to the system configuration is needed, or a control or 
receiver has been repaired or replaced. 

 

An MPCX control can operate up to eight scoreboards 
(receivers) in a dual type configuration. (All scoreboards must 
be in the same model series).  
 

Procedure to mate a control and receiver(s) 

Step 1.

 

Insert the batteries included with the MPCX control or turn the control ON by pressing 

Step 2.

 

Power up one to eight receivers using the 9V wall plug-in power supply provided with 
the receiver. Because all receivers powered up and within range of this control will be 
linked to this control with this procedure, power down all receivers not to be mated with 
new control. 

Step 3.

 

Press the               button until the display reads 

Step 4.

 

Enter the “Code” with the buttons in the sequence 

 

Step 5.

 

Continue pressing the               button until the display reads 

Step 6.

 

Press the            button. The control will link to all receivers in range.  

Step 7.

 

This process could take as long as 3 minutes. The control will automatically reset when 
linking is complete and each scoreboard connected to a “linked” receiver will light. 
Repeat steps 3 – 5 in the “Re-Mating” procedure below to ensure the correct number of 
receivers are linked indicated by 0/0 on the “Link Control screen”. The 0/0 on this screen 
indicates how many receivers are found / how many receivers are linked. 

If more receivers than intended are linked to the control, then power down any MPCX 
receivers in the area that are within 2000’ and repeat the process. If you cannot find these 
receivers, or they are located on an adjacent property, you may have to perform this 
process in another location. 

This process creates a list of receivers in the control. The control can only communicate 
with receivers on this list. The list remains intact even if the batteries are removed from 
the control. During normal operation (with any or all receivers ON), when you turn the 
control on, it searches for receivers on its list and the scoreboard(s) will light.

 

 

Note:

  During normal operation, the receiver should always be powered ON before the control. 

In a multi-control system, the controls must be powered ON and allowed to find the receiver one 
at a time. Wait about 30 seconds between powering-up controls. 

Link Control  0/0 

Press (+) 

Enter Code to 

Change Settings 

Link Control  0/0 

Press (+) 

Options 

HOME 

  Guests 

  + 

 - 

Options 

 + 

Содержание MPCX 1000

Страница 1: ...Rev 02 03 2011 135 0115 Scoreboard Operator s Instructions MPCX Baseball Control Since 1934 Retain this manual in your permanent files...

Страница 2: ...eatures of the scoreboard system Please take a few minutes to study this manual and to practice with the control If you ever have any questions or comments please call or email us NEVCO GUARANTEE To v...

Страница 3: ...nd hit error Add to or Subtract from the selected feature AT BAT TIME Team Batting Batter Number Timer Control Time Setting LCD Display 16 characters x 2 lines Power ON OFF Switch OPTIONS key Allows y...

Страница 4: ...H INNING BY INNING SCORING 3 SCOREBOARD WITH TIMER 5 KEYBOARD FUNCTIONS 8 GREETING SCREEN 8 MAIN SCREEN 9 BALL STRIKE OUT SCREEN 10 HIT ERROR HORN SCREEN 11 AT BAT SCREEN 12 TIME SCREEN 13 OPTIONS MEN...

Страница 5: ...iled instructions It is assumed that the receiver is powered ON Turn the Control ON Press The control will display a greeting while it establishes communications with its receiver s Up to 30 seconds N...

Страница 6: ...or then The BALL STRIKE and OUT keys are all additive adds one with each press of the key Press and hold the BALL or STRIKE key to reset the Balls and Strikes Press and hold the OUT key to reset the...

Страница 7: ...Press The control will display a greeting while it establishes communications with its receiver s Up to 30 seconds Next the display will show the inning and the score Note The cursor indicates the ac...

Страница 8: ...or then The BALL STRIKE and OUT keys are all additive adds one with each press of the key Press and hold the BALL or STRIKE key to reset the Balls and Strikes Press and hold the OUT key to reset the...

Страница 9: ...ing while it establishes communications with its receiver s Up to 30 seconds Next the display will show the inning the time status and the score Note The cursor indicates the active function Note If t...

Страница 10: ...s Note Hold the key down for fast advance Press The control will display Select the timer Direction Press The control will display Use the and keys to enable or disable the Auto Horn Press AT BAT TIME...

Страница 11: ...eys are all additive adds one with each press of the key Press and hold the BALL or STRIKE key to reset the Balls and Strikes Press and hold the OUT key to reset the Balls Strikes and Outs Please cons...

Страница 12: ...n it back ON Note If the scoreboard fails to respond to the control power the control OFF wait a few seconds and then try again Please allow time for each control to complete its powering ON process m...

Страница 13: ...efore turning ON another control Inn 1 Home Guest Strikes 0 HOME GUESTS INNING SCORE Inn 1 Home 0 Guest 0 Accessed by pressing MAIN The main screen shows the Inning the Timer Status for boards with ti...

Страница 14: ...e Out count by 1 Once selected you can also use the or keys to change the data Note Press and hold the OUT key to reset the Balls Strikes and Outs Balls 1 Outs 0 Strikes 0 BALL OUT STRIKE Balls 0 Outs...

Страница 15: ...key a third time to access the Horn Use the key to sound the Horn Note Some scoreboards may not have a horn HIT ERROR HORN Hits Home 0 Guest 0 HIT ERROR HORN Press for Horn HIT ERROR HORN Accessed by...

Страница 16: ...Use the or keys to enter the player number Note Hold the key down for fast advance At Bat G 45 AT BAT TIME Accessed by pressing AT BAT This screen is for entering the AT BAT information Use the HOME...

Страница 17: ...urn to the main screen Note Some timers will display tenths of seconds while others display only whole seconds In all cases the time is divided into fractions of a second for greater accuracy It may b...

Страница 18: ...the options key moves you to the next option screen Note In this illustration the cursor indicates the default factory settings Note You can return to the main screen at any time by pressing INNING S...

Страница 19: ...need not be changed and should only be changed by an experienced operator or under direction from the Nevco Service Department Press the following key sequence to gain access to the following additio...

Страница 20: ...o establish communications with its receiver s Greeting screen disappears before powering ON the next control Note Set the Security of ALL controls used in a multi control system to OFF Note When usin...

Страница 21: ...ol will link to all receivers in range Step 7 This process could take as long as 3 minutes The control will automatically reset when linking is complete and each scoreboard connected to a linked recei...

Страница 22: ...he options routine The last scoreboard type displayed will become the new control configuration For models 1500 1510 1530 1535 1550 1600 1610 1630 1635 1650 1000 1010 1030 1035 For models 1503 1506 15...

Страница 23: ...as left ON Scoreboard was left in high security mode Cycle power to receiver I cannot set the time The time is running Stop the time first Cannot turn the time ON Time at 0 0 and set to count down Set...

Страница 24: ...cations FCC part 15 Class B CE RoHS NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed...

Отзывы: