22
User Manual – DANTE
TM
Adapter NA2-IO-DPRO | BDA 573 V1 2019/08
Operation
5 Operation
5.1 Preparations
T
Unpacking the DPRO Adapter.
T
Save packaging for later transport and storage.
T
Check the packaging and DPRO Adapter for visible damage.
T
When visible damage to the packaging and/or delivered parts is detected:
Contact the salesperson or Neutrik sales partner.
T
Do not use damaged devices under any circumstances.
5.2 Connecting devices with the DPRO Adapter
The DPRO Adapter can be connected to a Dante
TM
network via a standard 1 Gbit/s twisted-pair
Ethernet cable (CAT5e). This connection is responsible for the data transfer as well as for the power
supply. Depending on the cable length and shield, we do not recommend installing cables parallel
to power supply lines.
The
DPRO Adapter
requires a switch that supports PoE (48 V). If a switch without
PoE support is available, a PoE injector (compatible with 802.3af or 802.3at) must
be connected in series.
w
CAUTION
Danger of hearing damage!
Signal peaks may occur when an audio source or sink is connected.
T
Before making connections, mute the signal path of the peripheral devices.
w
CAUTION
Danger of hearing damage!
Signal peaks may occur as a consequence of incorrect connections.
T
Do not connect AES/EBU signal to input 1.
T
Do not connect amplifiers or other analog devices to output 2 (AES) if there is no
connection on output 1 (ANA).
Front
Rear