Container Cleaning System TANKO®EX-R64T
10/80
Translation - Operating/installation instructions 2020/03
2 Safety
Operating state - idle state (NO cleaning > cleaning medium is NOT sprayed, TANKO-R64T and attached
spray heads are stationary)
Pressure in the container: Depending on the permissible maximum pressure of the attached fittings
including media supply. The media supply must be closed tightly, the cleaning device does not have
its own shut-off device
Ambient temperature in the container to be cleaned: -20 °C to 180 °C
The device was developed, engineered and built exclusively for industrial and commercial use. It must
not be used for private purposes.
Its use is also possible if there is a potentially explosive dust or gas atmosphere in the container to be
cleaned or if one could develop.
The TANKO-EX-R64T device is suitable for use in a potentially explosive atmosphere of Zone 0 or
Zone 20.
Only the TANKO-EX-S30 or TANKO-EX-RB-30 may be used as cleaning devices.
For the Ex marking, also note the additional information on the type label (see
section 2.5.3
Identification for Explosion Protection
.
The owner must always check whether the device is suitable for his application.
NOTE ON EXPLOSION PROTECTION
The area of application of the device must always be adapted to the corresponding
operating conditions and the materials in contact with the product. These materials must
be selected so that there are no reactions between them and the cleaning medium or the
substances in the container to be cleaned, which could impair explosion safety.
It must be ensured that no hybrid mixtures can develop in the container or in the
environment (a hybrid mixture is a mixture of air with flammable substances in different
aggregate states, e.g. gas / vapor and dust)
If this is not observed, the explosion protection could be disabled.
Locations for containers in which the device is to be installed are usually closed rooms. If the set-up is
different, the owner is responsible for ensuring the device is protected against harmful weather and
environmental influences in compliance with the specified operational limits / conditions (see
Section 3.3
Always observe the following:
Only operate the device when installed in a closed container.
Never point the cleaning jet or surge of the device at persons.
Protect the device from freezing (e.g. risk of frost from possible residual water).
Use a suitable filter system in the cleaning medium supply line.
Only operate the device within the approved parameters such as pressure and temperature
(see
Section
). If necessary, appropriate monitoring and limiting systems
(e.g. for pressure and temperature) must be used.
Only cleaning media that are compatible with the materials of the device may be used (see
Section