10
| KH 120
The following settings can be used as a starting point for further adjustment:
Loudspeaker position
Acoustical controls
Bass
Low-Mid
Treble
In a corner
-
7 .5 dB
-
1 .5 dB
–
Next to an acoustically solid wall (e .g . brick, concrete)
-
5 dB
–
–
Next to an acoustically soft wall (e .g . gypsum)
-
2 .5 dB
–
–
Free standing in an untreated room
-
2 .5 dB
–
-
1 dB
Free standing in a well-treated room
–
–
–
In a small room with strong side wall reflections
-
5 dB
0 dB
–
Near a small desktop or small reflecting surface*
–
-
1 .5 dB
–
Near a large desktop or large reflecting surface*
–
-
3 dB
–
*
Use these settings in addition to one of the top five settings
Adjusting the acoustic level
X
On your KH 120 loudspeakers, set the output level control (“OUTPUT LEVEL”) to 94 dB SPL
and the input gain control (“INPUT GAIN”) to
-
15 dB .
X
Play a broadband pink noise test signal that is set to
-
18 dBFS (Europe) or
-
20 dBFS (USA)
on the mixing console’s output level meters .
X
Measure the sound pressure level at the listening position using a sound level meter with
the following settings:
•
“C”-weighted
•
slow integration time
X
Set the output level and input gain controls of your loudspeakers so that the desired acous-
tic level is obtained .
Recommended sound pressure levels:
Application
Sound pressure level
Film
85 dB(C)
Broadcast
79 to 83 dB(C)
Music
No defined reference levels
If the Neumann logo flashes red, the loudspeakers’ protection system has been activated . To
avoid this and achieve the desired output level, use larger loudspeakers or add a bass man-
aged subwoofer to the system .