Quick start procedure: 

 

PC or Mac Computer 

 

Materials needed: 
 

 

NUL-219 Colorimeter Sensor  

 

Cu Cuvette Lids 

 

USB-200 USB Module 

 

A USB to mini USB cable (which comes with the USB-200) 

 
Your colorimeter sensor needs to be connected to a USB-200 module.  The USB-200 
module then connects to a computer via a USB to mini-USB cable.  Please note that 
you cannot plug the colorimeter sensor directly into the computer. 
 
Resident  PC  software  and  browser  based  software  can  be  downloaded  for  free  at 
www.NeuLog.com/dowload as well as a full software user guide.

  Note:

 Make sure not 

to download and install both types of software, they will conflict on the computer. 
 

Procedure: 

 

1. 

Install the NeuLog software 

2. 

Connect the USB-200 module to the PC or Mac 

3. 

Connect the colorimeter sensor to the USB-200 module (they directly plug 
together).  Please note there is no calibration required for this sensor. 

4. 

Open the NeuLog software. 

5. 

Once a colorimeter sensor logo appears on the left side of the screen the 
probe has been automatically identified and you can begin experimentation. 

6. 

If the colorimeter sensor is not automatically identified then click the “Search 
for sensors” icon to find the sensor. 

7. 

Select the “On-line experiment” button; this will open a graph below. 

8. 

Click on the “Module setup” button located on the colorimeter sensor icon in 
the module window to change the sensor settings if need be. 

9. 

Click on the experiment set up button to change the experiment settings if 
need be (experiment duration for example). 

10.  The colorimeter sensor will give a live reading in the box to the left of the 

screen while plugged in. 

11. 

To run an experiment and collect data click “Run experiment”. 

12. 

To end data collection early, click “Stop experiment”. 

 

Tablet, smart phone device 

 

Materials needed: 
 

 

NUL-219 Colorimeter Sensor 

 

Cu Cuvette Lids 

 

WIFI-201 WIFI module 

 

BAT-200 Battery 

 
Your colorimeter sensor needs to be connected to a WIFI-201 module. The WIFI-201 
module will create a closed NeuLog wifi network which will stream the NeuLog data to 
a  device  of  your  choosing.  Once  your  device  is  wirelessly  connected  to  the  NeuLog 
network you can run experiments and collect data through a browser of your choosing. 
 

Procedure: 

 

1. 

Connect the colorimeter sensor directly to the left side of a WIFI-201 module 
(no wires required). 

2. 

Connect a BAT-200 module to the right side of the WIFI-201 module. 

3. 

Although not required, we recommend plugging the BAT-200 to an outlet 
using a USB to micro USB charger (such as a typical cell phone charger).  
The WIFI-201 module will run for 15-75 minutes (depending on the sensor) 
without being plugged in. 

4. 

For further WIFI-201 instructions or the WIFI-201 quick start guide please 
visit 

www.NeuLog.com/download

. 

5. 

The WIFI-201 indicator lights will flash; take no action until the LED to the 
far left turns blue. 

6. 

Take your tablet or smart phone and go to the Wi-Fi settings and select the 
NeuLog network which matches the WIFI module ID found on the back of 
the WIFI-201 device. (NeuLogXXXX for example) 

7. 

Give your device 1-2 minutes to connect to the WIFI-201 network. 

8. 

Once the device is connected go to your browser and type in the website 
wifi201.com into the URL bar, then wait for 30-60 seconds. 

9. 

You will see a “Control mode” icon in the browser, click on this icon. 

10.  The browser will then load a new screen and begin to auto detect the 

sensors, this can take a few minutes. 

11. 

If the browser does not auto detect, select “Search for sensors” 

12.  Once the sensor is found you will see an icon on the left side of the screen 

for the colorimeter sensor.  The icon will display data in real time. 