10
NX-507E / NX-508E AUXILIARY MODULES
Segment 2 Selects the following partitions:
LED 1 - "On" if the event should activate when it occurs in Partition 1.
LED 2 - "On" if the event should activate when it occurs in Partition 2.
LED 3 - "On" if the event should activate when it occurs in Partition 3.
LED 4 - "On" if the event should activate when it occurs in Partition 4.
LED 5 - "On" if the event should activate when it occurs in Partition 5.
LED 6 - "On" if the event should activate when it occurs in Partition 6.
LED 7 - "On" if the event should activate when it occurs in Partition 7.
LED 8 - "On" if the event should activate when it occurs in Partition 8.
Location 2
Enabling the Schedules for Output 1
(1 segment of binary data) Location 2 is used to enable any or all of the eight (8) schedules. LED 1 corresponds
to Schedule 1 (see locations 32-34, page 10) and LED 8 corresponds to Schedule 8 (see locations 53-55, page 11).
This location can be used in conjunction with the Special Function location to create an output that will only
activate during certain times and/or certain days.
LED 1 - "On" if the event should follow Schedule 1.
LED 2 - "On" if the event should follow Schedule 2.
LED 3 - "On" if the event should follow Schedule 3.
LED 4 - "On" if the event should follow Schedule 4.
LED 5 - "On" if the event should follow Schedule 5.
LED 6 - "On" if the event should follow Schedule 6.
LED 7 - "On" if the event should follow Schedule 7.
LED 8 - "On" If the event should follow Schedule 8.
Location 3
Programming the X-10 Address for Output 1
(2 segments of numerical data)
Segment 1
Program a number from 0-15 to represent the corresponding X-10
Module Number
from the
following table.
Module
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Seg 1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Segment 2
Program a number from 0-15 to represent the corresponding X-10
House code
from the
following table.
X-10 ADDRESS CODES
0=A 4=E 8=I 12=M
1=B 5=F 9=J 13=N
2=C 6=G 10=K 14=O
3=D 7=H 11=L 15=P
Locations 4 - 31 Programming For Outputs 2- 8
Locations 4 - 31 are used to program the events, zones and times, as well as the special functions, partitions,
schedules and X-10 addresses for Outputs 2 - 8. Each output has four locations that are programmed with
the same steps as Output 1 described previously. Refer to Output 1 for specific instructions (locations 0 - 3,
pages 9-10). Also refer to the worksheets beginning on page 14.
Location 32
Programming the Opening Time for Schedule 1
(2 segments of numerical data)
Segment 1
Program the hour of the opening time in 24-hour format. (1:00 PM = 13)
Segment 2
Program the minutes after the hour of the opening time for Schedule 1.