NX-507E / NX-508E AUXILIARY MODULES
9
X.
PROGRAMMING
LOCATIONS
Location 0
Programming the Event, Zone and Time for Output 1
(3 segments of numerical data) Location 0 is used to select the particular function, zone number, and time for
an output to trip.
Segment 1 (EVENT)
Selects the event that will trigger the output. See chart below for the specific
vents that can be selected
.
e
Segment 2 (ZONE/USER)
Selects the zone or user number necessary to trigger an output. If this location is
programmed as a zero, any zone or user will activate the output. (See also loc. 68,
age
p
11)
Segment 3 (TIME)
Selects the amount of time an output will remain activated when an output
triggers. If this location is programmed as a zero, the output will follow the
particular event.
#
Event
#
Event
#
Event
0
/
Burglary Alarm
20
Entry or Exit
40
Box Tamper
1
/
Fire Alarm
21
Armed
41
Siren Tamper
2
/
24 Hour Alarm
22
Not Armed
42
Any Zone Faulted
3
/
Zone Trouble
23
Ready
43
/
Any Alarm
4
/
Zone Tamper
24
Not Ready
44
Keypad Beeping
5
Burglary Siren
25
Fire
45
/
Code Entry
6
Fire Siren
26
Fire Trouble
46
:
Key FOB Function 1
7
Any Siren
27
Chime
47
:
Key FOB Function 2
8
Zone Bypass
28
/
Expander Trouble
48
Auto Arm Control
9
AC Failure
29
Dynamic Battery Test
49
Auto Disarm Control
10
System Low Battery
30
Open Schedule
50
Auto Arm & Disarm Control
11
/
Duress
31
Closed Schedule
51
Follow schedule of NX-508E
12
/
Manual Fire
32
Listen In
52
Flash X-10 for Alarm Memory
13
/
Aux 2 Keypad
33
Line Seizure
53
Flash X-10 for Siren
14
/
Keypad Panic
34
Failed to Communicate
54
Armed Away (Exit Expired)
15
Keypad Tamper
35
Telephone Line Fault
55
End Listen In (Integrated Only)
16
/
Automatic Test
36
Program Mode
56
Follow X-10 Command
17
Alarm Memory
37
Download
57
Armed Stay
18
Entry
38
Ground Fault
19
Exit
39
Over Current
See loc. 52 & 53 in NX control panel
/
If set to follow condition, these events will be 1 second.
:
Events 46 & 47 require NX-408E, NX-416E, or NX-448E wireless receivers to operate. Events 48, 49, and 50 will arm
or disarm the NX control panel at the open (disarm) or close (arm) time for the appropriate schedule. See
example 3 on page 13.
Location 1
Programming Special Functions and Partitions for Output 1
(2 segments of binary data)
Segment 1 Selects the following special conditions:
Address
Output
24 1-8
25 9-16
26 17-24
27 25-32
28 33-40
29 41-48
30 49-56
31 57-64
LED 1 - "On" if output should time in minutes; "Off" if output times in seconds.
LED 2 - "On" if output should latch until a code is entered.
LED 3 - "On" if output should reset if a code is entered while it is being timed.
LED 4 - "On" if output should only trigger during a closed schedule.
LED 5 - "On" if output should only trigger during an open schedule.
LED 6 - "On" if the output should be inverted.
LED 7 - "On" if a trigger should be logged in the event buffer. See chart.