NX-1700E Card Reader 

22 

LOC 

PG 

DESCRIPTION 

DEFAULT 

YOUR DATA 

283 

15 

ACTIVATION DATA FOR USER CARDS 121 - 240 

 

 

1 =  

User Cards 121 – 128 

2 =  

User Cards 129 – 136 

3 =  

User Cards 137 – 144 

4 =  

User Cards 145 – 152 

5 =  

User Cards 153 – 160 

6 =  

User Cards 161 – 168 

7 =  

User Cards 169 – 176 

8 =  

User Cards 177 – 184 

9 =  

User Cards 185 – 192 

10 =  

User Cards 193 – 200 

11 =  

User Cards 201 – 208 

12 =  

User Cards 209 – 216 

13 =  

User Cards 217 – 224 

14 =  

User Cards 225 – 232 

15 =  

User Cards 233 – 240  

 

 

 
 
 

IX. ORDERING 

INFORMATION 

 

PART # 

DESCRIPTION 

PART # 

DESCRIPTION 

NX-1700E 

Card Reader Module 

NX-148E 

Alphanumeric 48 Zone LCD Keypad 

NX-8E  

8 – 192 Zone Control Only 

NX-1192E 

192 Zone LCD Keypad 

NX-848E-KIT  NX-8E Control, NX-148E LED Keypad, 

40VA Transformer 

NX-216E 

16 Zone Expander Module 

NX-8 

8 – 48 Zone Control Only 

NX-320E 

Smart Power Supply and Buss Extender 

NX-848-KIT 

NX-8 Control, NX-148E LED Keypad, 
40VA Transformer 

 NX-408E 

8 Zone Wireless Expansion Module 

NX-6 

6 – 12 Zone Control Only 

 NX-416E 

16 Zone Wireless Expansion Module 

NX-648-KIT   NX-6 Control, NX-148E LED Keypad, 

40VA Transformer 

 NX-448E 

48 Zone Wireless Expansion Module 

NX-4 

4 Zone Control Only 

NX-507E 

Seven Relay Module 

NX-4-KIT-7 

NX-4 Control, NX-148E LED Keypad, 
40VA Transformer 

NX-508E 

Eight Output Module 

 

 

NX-534E 

Two-Way Listen In Module 

 

 

 

 

 

  These units are UL listed for residential use only. 

 
 
 

LED1 = Card 1 
LED2 = Card 2 
LED3 = Card 3 
LED4 = Card 4 
LED5 = Card 5 
LED6 = Card 6 
LED7 = Card 7 
LED8 = Card 8 

 

Содержание NX-1700E

Страница 1: ...NX1700EIE03 Supercedes NX1700EID03 NetworX Series NX 1700E Proximity Card Reader Installation and Startup...

Страница 2: ...GE Interlogix Please refer to the current GE Interlogix product catalog for detailed warranty information Main 800 727 2339 Technical Support 800 727 2339 Outside the US 903 845 6941 Tech Support Fax...

Страница 3: ...er Partition 11 Location 243 Programming the Zones 12 Location 244 Programming the Various Reader Timers 12 Location 245 Resetting the Reader Address 13 Location 246 Programming the Access Options 13...

Страница 4: ...E EGRESS This is an optional EGRESS exit input To use this feature connect the normally open egress switch between this terminal and COM If this feature is not used there is no need to connect this wi...

Страница 5: ...possible addresses Table IV 1 Beeps Address Beeps Address 1 113 9 121 2 114 10 122 3 115 11 123 4 116 12 124 5 117 13 125 6 118 14 126 7 119 15 127 8 120 V PROGRAMMING A USING THE LED KEYPAD ACTION R...

Страница 6: ...is saved The new data is saved The keypad will increment and display the next segment s data NOTE Repeat these steps until the last segment is reached To Exit a Location Exits from this location The R...

Страница 7: ...t is recommended that only one reader on the system be enabled to modify user cards and that this reader be located near a keypad This reader will transfer information to all other readers in the syst...

Страница 8: ...ion ADDING MULTIPLE USERS WITH AUTO INCREMENT ACTION RESULT CANCEL Accesses Activation mode 3 digit user number Example if 4 digit user code or if 6 digit user codes If a valid user number is entered...

Страница 9: ...readers will begin to flash Scan any card The card information for the user entered in the previous step will be cleared and LED1 will stop flashing After about 30 seconds all the readers in the syst...

Страница 10: ...rol panel LED7 On to broadcast an X 10 function see Location 241 for programming LED8 On to send a Request To Exit RTE and activate the onboard open collector output Default is On Location 243 Segment...

Страница 11: ...e same as for Single Beep Scan Function This location only needs to be programmed if Location 0 Segment 3 Option 7 is set Use the above table Default is 2 LOCATION 242 PROGRAMMING THE OPTIONS AND READ...

Страница 12: ...as a door for access control This location must be programmed with a valid zone for monitored access control functions to work properly Default is 0 Additionally this zone must be configured in the c...

Страница 13: ...address then it will sound an error beep LOCATION 246 PROGRAMMING THE ACCESS OPTIONS 2 segments of binary data Segment 1 Door Options LED1 On if locking mechanism is a Maglock or Drop Bolt LED2 On if...

Страница 14: ...e for specific instructions Location 250 Opening Time for Schedule 2 Location 262 Opening Time for Schedule 6 Location 251 Closing Time for Schedule 2 Location 263 Closing Time for Schedule 6 Location...

Страница 15: ...er Cards 9 16 Segment 10 User Cards 73 80 Segment 3 User Cards 17 24 Segment 11 User Cards 81 88 Segment 4 User Cards 25 32 Segment 12 User Cards 89 96 Segment 5 User Cards 33 40 Segment 13 User Cards...

Страница 16: ...on to the control panel 5 On to send Auxiliary Function 1 to the control panel 6 On to send Auxiliary Function 2 to the control panel 7 On to broadcast an X 10 function Loc 241 for programming 8 On to...

Страница 17: ...uzzer follows keypad buzzing 4 On if ding dong chime enabled Opt 3 chime must be enabled 5 On if an RTE from a scanned card is to be logged as Code Entry 6 On if reader is in NX 1700E Legacy Mode 7 On...

Страница 18: ...00000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000000 00000000000000000000000000000000000000...

Страница 19: ...s active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 253 14 OPENING TIME FO...

Страница 20: ...s active on Wednesday 5 On if schedule is active on Thursday 6 On if schedule is active on Friday 7 On if schedule is active on Saturday 8 On if schedule is disabled on holidays 262 14 OPENING TIME FO...

Страница 21: ...holidays 271 14 HOLIDAYS IN JANUARY 8 max No holidays _ _ _ _ _ _ _ _ 272 14 HOLIDAYS IN FEBRUARY 8 max No holidays _ _ _ _ _ _ _ _ 273 14 HOLIDAYS IN MARCH 8 max No holidays _ _ _ _ _ _ _ _ 274 14 HO...

Страница 22: ...1192E 192 Zone LCD Keypad NX 848E KIT NX 8E Control NX 148E LED Keypad 40VA Transformer NX 216E 16 Zone Expander Module NX 8 8 48 Zone Control Only NX 320E Smart Power Supply and Buss Extender NX 848...

Страница 23: ...egacy mode Request To Exit RTE A zone can be programmed to monitor an open door The RTE activates the onboard open collector output and sends a message on the buss Scan To present or pass a card or FO...

Страница 24: ...A Standby with Green LED 110mA Maximum OPERATING TEMPERATURE 31 to 151 degrees F 35 to 66 degrees C SHIPPING WEIGHT 1 lb 1420 N MAIN STREET GLADEWATER TEXAS 75647 Main 800 727 2339 Technical Support 8...

Отзывы: