NTI SERIMUX SERIES CONSOLE SWITCH
21
Advanced Settings
From the "Administrator main menu", press [
7
] to display the “Advanced settings” menu.
Figure 17- Administrator's Advanced settings menu
From the "Advanced settings" menu the administrator can perform the following functions:
Setting
Description
Value
Administrator
Password
Define the password to be used by the
administrator
Max. 31 characters.
This can only be changed if old password is known.
(If SERIMUX is re-initialized (pg 34), the default password
(“NTI”) will be restored)
Administrator
Timeout
the time interval of administrator
inactivity, prior to logging out.
0-90 minutes 0 = Never
Unit name
Name assigned to the SERIMUX
Max. 40 characters
User to auto login
User assigned to automatically login at
power up without a password.
Index number of any enabled user that has access to the port
being used for the user port
Connect two host
ports
Connect two host ports together
Enter host port index number, press [Enter], second host port
index number, and press [Enter] again
Firmware
Display the firmware menu
See pg. 22
Auto Refresh Period
Refreshes the admin screen after xx
minutes
0-90
Local KeyPad PIN
Defines the PIN number for Local
keypad
4 digit value 0000-9999 (default value is 9999 for most
models, 4444 in SERIMUX-CS-4)
Network Settings
Define all network connection settings
See “Network Settings’” - page 23
FYI: If at power up the auto-login user does not have access to port being used, a login by a valid user with
access rights will be required.
Change administrator password
For security purposes the administrator should change the factory default administrator password to a unique password. This will
prevent unauthorized access to switch functions and CPUs. The password is needed to log in from any device, connected to any
SERIMUX port in buffer mode.
To change the administrator password, from the Administrator main menu;
-
press [
7
] to choose Advanced settings and press [
Enter
]. The Advanced settings menu will appear (Fig. 17)
-
press [
1
] and a prompt for the old password will appear
-
enter the old password (factory default password is "
nti
") and press [
Enter
]
-
enter a new password (maximum 31 ASCII characters), using the [Backspace] key to erase any characters entered
in error, and press [
Enter
]
-
re-enter the password to confirm it, and press [
Enter
]
-
a message "OK" will appear, press any key to return to the Advanced settings menu
NOTE: The password entered will be case sensitive so be sure to note what characters are upper or lower case if any are
alphabetical. The password characters are displayed as ‘*’ (asterisk) characters while entering them.
NOTE:
If the administrator password is not known, the administrator must re-initialize the SERIMUX following the "Reset
SERIMUX Console Switch to default settings" instructions on page 34.