11

Declaration of conformity with CE 

This apparatus meets the requirements of EN 55103-1 (November 1996) with regard to emissions, and 
EN 55103-2 (November 1996) with regard to immunity; it thereby complies with the Electromagnetic 
Compatibility Directive 89/336/EEC. 

 

 

General environmental requirements for Network flashlink

®

 equipment 

1.

 

The equipment will meet the guaranteed performance specification under the following environmental 
conditions: 

 

 

Operating room temperature range 

0°C to 40°C   

 

Operating relative humidity range 

up to 90% (non-condensing) 

 
 

2.

 

The equipment will operate without damage under the following environmental conditions: 

 

 

Temperature range 

 

 

-10°C to 50°C 

 

Relative humidity range   

 

up to 95% (non-condensing) 

 
 

3.

 

Electromagnetic compatibility conditions: 

 

 

Emissions 

    EN 

55103-1 

(Directive 

89/336/EEC) 

 

Immunity 

    EN 

55103-2 

(Directive 

89/336/EEC) 

 

 

  

Содержание DA-HDSDI

Страница 1: ...HD SDI Distribution Amplifier Network Electronics ASA Thor ya N 3204 Sandefjord Norway Phone 47 33 48 99 99 Fax 47 33 48 99 98 e mail support network electronics com www network electronics com E mail...

Страница 2: ...evision history The latest version is always available in pdf format on our web site http www network electronics com Current revision of this document is the uppermost in the table below Revision Rep...

Страница 3: ...l 4 2 Specifications 5 3 Format Configuration 6 3 1 Configuration Examples 7 4 Connector module 8 4 1 Mounting the connector module 8 5 Module status 9 5 1 GPI ALARM Module Status Outputs 9 5 2 Front...

Страница 4: ...nd SD rates and automatically switch to correct output slew rate The re clocker supports the bit rates 143 177 270 360 540 and 1485Mbps For other rates the re clocker automatically switches to bypass...

Страница 5: ...Number of outputs 6 Connector BNC Impedance 75 ohm Return loss 15dB acc to ITU R BT 1120 3 Jitter max 0 2UI Peak to peak signal level 0 8V 0 1V Signal polarity 3 non inverting 3 inverting Features Re...

Страница 6: ...ting of equaliser when signal strength is to low Input mute 3 RCL Reclocker Bypass Reclocker ON Reclocker mode 4 EQ Cable equaliser Bypass Cable equaliser ON Equaliser mode 5 ASI SDI 177Mbps Reclocker...

Страница 7: ...ypical configurations for DA HDSDI Figure 3 Default HD SDI SDI and DVB ASI Figure 4 Transparent Mode with equalisation and no reclocking Figure 5 AES3id compatible and Transparent Mode without equalis...

Страница 8: ...NC and the electrical outputs are connected to the O1 to O6 BNC Please note that O2 O4 and O6 has an inverted signal so formats like DVB ASI can not use be used on these outputs Unused outputs should...

Страница 9: ...oller is described in a separate user manual 5 1 GPI ALARM Module Status Outputs These outputs can be used for wiring up alarms for third party control systems The GPI outputs are open collector outpu...

Страница 10: ...has 4 LED s each showing a status corresponding to the GPI pinning The position of the different LED s is shown in figure 8 Diode state Red LED Yellow LED Green LED No light Status Module is faulty Mo...

Страница 11: ...y it thereby complies with the Electromagnetic Compatibility Directive 89 336 EEC General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performanc...

Страница 12: ...m Web http www network electronics com Technical specifications are subject to be changed without notice 12 Product Warranty The warranty terms and conditions for the product s covered by this manual...

Страница 13: ...period This is defined as the period of normal use before any hazardous material is released to the environment The guidance on how the EFUP is to be calculated is not finalised at the time of writin...

Страница 14: ...network electronics com Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require Where it is not possible to return the...

Отзывы: