background image

ADC-SDI-CC  

 

   

Rev. 3

 

DATE: 23 July 2008 

 

 

 

 

 

                                                   

Network Electronics AS, P.O.Box 1020, N-3204 Sandefjord, Norway. Tel.: +47 33 48 99 99 – Fax: +47 33 48 99 98 
E-mail: [email protected] – Web: http://www.network-electronics.com/ 
 
Technical specifications are subject to be changed without notice. 

 

 

18

Materials declaration and recycling information 

Materials declaration 

For product sold into China after 1st March 2007, we comply with the “Administrative Measure on the 
Control of Pollution by Electronic Information Products”.  In the first stage of this legislation, content of 
six hazardous materials has to be declared.  The table below shows the required information. 
 

Toxic or hazardous substances and elements 

 

組成名稱

 

Part Name 

 

Lead 

(Pb) 

 

Mercury 

(Hg) 

 

Cadmium

(Cd) 

六价铬

 

Hexavalent 

Chromium

(Cr(VI)) 

多溴联苯

 

Polybrominated 

biphenyls  

(PBB) 

多溴二苯醚

 

Polybrominated 

diphenyl ethers

(PBDE) 

 ADC-SDI-CC 

O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for 
this part is below the limit requirement in SJ/T11363-2006. 
 
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous 
materials used for this part is above the limit requirement in SJ/T11363-2006. 

 

Environmentally-friendly use period  

The manual must include a statement of the “environmentally friendly use period”.  This is defined as the 
period of normal use before any hazardous material is released to the environment.  The guidance on how 
the EFUP is to be calculated is not finalised at the time of writing.  See 

http://www.aeanet.org/GovernmentAffairs/qfLeOpAaZXaMxqGjSFbEidSdPNtpT.pdf 

for an unofficial 

translation of the draft guidance. For our own products, Network Electronics has chosen to use the 

50 

year figure

 recommended in this draft regulation.  

Network Electronics suggests the following statement on An “Environmentally Friendly Use Period” 
(EFUP) setting out normal use:  

EFUP is the time the product can be used in normal service life without leaking the hazardous materials.  We expect the normal 
use environment to be in an equipment room at controlled temperature range (0ºC - 40ºC) with moderate humidity (< 90%, non-
condensing) and clean air, not subject to vibration or shock.   

Further, a statement on any hazardous material content, for instance, for a product that uses some tin/lead 
solders: 

Where a product contains potentially hazardous materials, this is indicated on the product by the appropriate symbol containing 
the EFUP.  The hazardous material content is limited to lead (Pb) in some solders.  This is extremely stable in normal use and the 
EFUP is taken as 50 years, by comparison with the EFUP given for Digital Exchange/Switching Platform in equipment in 
Appendix A of “General Rule of Environment-Friendly Use Period of Electronic Information Products”.  This is indicated by the 
product marking: 

Содержание ADC-SDI-CC

Страница 1: ...network electronics com Multi standard NTSC PAL YPbPr RGB Decoder Converter Component and Composite Analogue Video Converter Rev 3 Flashlink User Manual ADC SDI CC...

Страница 2: ...istory The latest version is always available in pdf format on our web site http www network electronics com Current revision of this document is the uppermost in the table below Revision Replaces Dat...

Страница 3: ...Configuration and Setup 8 4 1 Setting the DIP switches 8 4 2 Reset 10 5 Module status 11 5 1 GPI ALARM Module Status Outputs 11 5 2 Front Panel Status Monitoring 12 6 Interface with GYDA and RS 422 c...

Страница 4: ...backplane module see Figure 2 on page 7 4 Power on After some seconds the ADC SDI CC will be running and the input detected All LED s will be green and the SDI output active If this is not the case p...

Страница 5: ...se ratio for each input channel When used with the GYDA control system gain adjustments may be made to each analogue input Composite video decoding utilises a 5 line adaptive comb filter for both the...

Страница 6: ...Hz or NTSC 525 60Hz Y C S video Connector BNC Impedance 75 ohm Signal level 1Vp p Return loss 40dB Component and RGB Input Signal rate 625 50Hz or 525 60Hz Signal type RGB without setup with separate...

Страница 7: ...connectors and signals The ADC SDI CC C1 connector module has 7 BNC s CVBS Y Analogue input CVBS SYNC for RGB or S Video Luma R Pr Analogue input Red or component Pr G Y Analogue input Green or compo...

Страница 8: ...nterface to some of the most used features of t A top of the card see Figure 3 h is off when Function Comment 1 Manual mode on off When on enables switches 2 3 4 5 6 and 8 2 Input Channel select 3 Inp...

Страница 9: ...S 0 1 S Video 1 0 YPbPr 1 1 RGBS Table 2 Manual selection of video mode Mark Field 1 feature is enabled and the card inserts a marker on line x of each field This features gives improved encoding qual...

Страница 10: ...ault values This is flagged by the Card State LED which starts to blink yellow 4 Power down 5 Turn switch 8 off If you want the DIP switches to be placed in the factory default position this is the ti...

Страница 11: ...described on the next page The GYDA controller is described in a separate user manual This manual is available on our web site http www network electronics com 5 1 GPI ALARM Module Status Outputs Thes...

Страница 12: ...n Figure 5 below Text not printed on the front panel Figure 5 Front panel indicator for ADC SDI CC The ADC SDI CC has 4 LED s each showing status information The position of the different LED s is sho...

Страница 13: ...format to CVBS Svideo OK Set video format to S Video RGB OK Set video format to component RGB sync YPbPR OK Set video format to component YPbPr MarkF1 on OK Turn on the Mark Field 1 feature MarkF1 of...

Страница 14: ...Locked to 625 lines 50 Hz Locked 60Hz Locked to 525 lines 60 Hz Not locked 50Hz Not locked previously locked to 50Hz Analogue input Not locked 60Hz Not locked previously locked to 60Hz Field 1 marking...

Страница 15: ...tp www network electronics com Technical specifications are subject to be changed without notice 15 6 5 Mark Field 1 Pedestal and Comb commands Commands to turn on off the Mark Field 1 feature Pedesta...

Страница 16: ...hout notice 16 General environmental requirements for Network flashlink equipment 1 The equipment will meet the guaranteed performance specification under the following environmental conditions Operat...

Страница 17: ...m Web http www network electronics com Technical specifications are subject to be changed without notice 17 Product Warranty The warranty terms and conditions for the product s covered by this manual...

Страница 18: ...eriod This is defined as the period of normal use before any hazardous material is released to the environment The guidance on how the EFUP is to be calculated is not finalised at the time of writing...

Страница 19: ...be supported for 50 years Recycling information Network Electronics provides assistance to customers and recyclers through our web site http www network electronics com Please contact Network Electron...

Страница 20: ...DEL NUMBER S ADC SDI CC DESCRIPTION Component and Composite Analogue Video Converter DIRECTIVES this equipment complies with LVD 73 23 EEC EMC 2004 108 EEC HARMONISED STANDARDS applied in order to ver...

Отзывы: