background image

2

1. Introduction

RA02A is a smoke sensor which is the Class A device based on LoRa private protocol of Netvox. It is compatible with the Netvox

LoRa protocol.

Note:

RA02A is an auxiliary smart smoke sensor which must be installed with the fire-fighting smoke sensor. RA02A cannot be used to

replace the fire-fighting smoke sensor.

LoRa Wireless Technology:

LoRa is a wireless communication technology famous for its long-distance transmission and low power consumption. Compared

with other communication methods, LoRa spread spectrum modulation technique greatly extend the communication distance. It

can be widely used in any use case that requires long-distance and low-data wireless communications. For example, automatic

meter reading, building automation equipment, wireless security systems, industrial monitoring. It has features like small size,

low power consumption, long transmission distance, strong anti-interference ability and so on.

LoRaWAN:

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and

gateways from different manufacturers.

This device has been certified by the LoRa Alliance and is allowed to use the following logo on the product:

Содержание RA02A

Страница 1: ...ontains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other parties in whole or in part without...

Страница 2: ...1 Table of Content 1 Introduction 2 2 Appearance 3 3 Main Feature 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Important Maintenance Instruction 10...

Страница 3: ...ds LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For exampl...

Страница 4: ...d alerts can be set via SMS text and email optional Applicable to the third party platforms Actility ThingPark TTN MyDevices Cayenne Low power consumption and long battery life Note Battery life is de...

Страница 5: ...search the network The green indicator stays on for 5 seconds success The green indicator remains off fail Had joined the network Turn on the device to search the previous network The green indicator...

Страница 6: ...hen the temperature is higher than 60 degrees Celsius the buzzer will alarm the red indicator will flash and a report will be sent immediately The fire alarm bit is 1 If the alarm continues the report...

Страница 7: ...00000000 Configuration failure 2 Read Configuration Downlink 020A000000000000000000 Response 820A003C003C0100000000 Current configuration Description Device CmdID Device Type NetvoxPayLoadData Config...

Страница 8: ...M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 2 8V Does not report Wakes up and collects data REPORTS 2 8V Wakes up and collects data REPORT 2 8V Wakes up and collects data REPO...

Страница 9: ...rts according to MinTime interval If the data variation is not greater than the last data reported the device reports according to MaxTime interval 3 We do not recommend to set the MinTime Interval va...

Страница 10: ...e will send an alarm message When the smoke concentration is lower than the set value and the regular reporting time is up the device will return to the normal state and send the normal message 3 RA02...

Страница 11: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: