7
5.2 Example of ConfigureCmd
FPort
:
0x07
Bytes
1
1
Var (Fix =9 Bytes)
CmdID
DeviceType
NetvoxPayLoadData
CmdID
– 1 byte
DeviceType
– 1 byte – Device Type of Device
NetvoxPayLoadData
– var bytes (Max=9bytes)
(1) Configure the R72615A parameters: MinTime = 30s, MaxTime = 3600s
Downlink: 0109001E0E100000000000
Devices return:
8109000000000000000000 (the configuration is successful)
8109010000000000000000 (the configuration is failed)
(2) Read the R72615A device configuration parameters
Downlink: 0209000000000000000000
Devices return:
8209001E0E100000000000 (device current configuration parameter)
Description
Device
CmdID DeviceType
NetvoxPayLoadData
ConfigReportReq
R72615A
0x01
0x09
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Reserved
(5Bytes,Fixed 0x00)
ConfigReportRsp
0x81
Status(0x00_success)
Reserved (8Bytes,Fixed 0x00)
ReadConfig
ReportReq
0x02
Reserved (9Bytes,Fixed 0x00)
ReadConfig
ReportRsp
0x82
MinTime
(2bytes Unit:s)
MaxTime
(2bytes Unit:s)
Reserved