4.Set up Instruction
On/Off
Power on
Connect to battery pack
Turn on
Connect the battery pack directly to boot
Turn off (Restore to factory setting) Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Power off
Remove battery pack
Note:
1.
On/off interval is suggested to be about 10 seconds to avoid the interference of capacitor
inductance and other energy storage components.
2.
The engineering test requires to write the engineering testing software separately.
Network Joining
Never joined the network
Turn on the device to search the network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Had joined the network
Turn on the device to search the previous network to join.
The green indicator stays on for 5 seconds: success
The green indicator remains off: fail
Function Key
Press and hold for 5 seconds
Restore to factory setting / Turn off
The green indicator flashes for 20 times: success
The green indicator remains off: fail
Press once
The device is in the network: The green indicator flashes once,R72615A will send first data
after 180 seconds then send second data after 30 seconds again.
The device is not in the network: green indicator remains off
Restore to Factory Setting
Description
The R72615A carries a power-off network information saving memory function. This feature is
turned off by default, that is, it will be re-joined every time it is powered back on. The function
can be turned on by the ResumeNetOnOff command. At this time, each time the power is
rewritten, the last joining information will be recorded (including saving the network address
information assigned to it, etc.) and it will not be re-joined again. If you want to join a new
network, you need to perform a factory setting operation first.
Operation method
1. Press and hold the button for 5 seconds and release (the button is released when the LED
flashes), and the LED flashes 20 times;
2. The device automatically restarts to start re-joining.