The device and battery pack can be installed on the wall or other object surface. 

 

 

 
 
 
           
 
 
 
 
 
 
 

 

 

 

Note: Do not install the device in a metal shielded box or environment with other electrical equipment around it to avoid   

affecting the wireless transmission of the device.

 

 
 

5.

 

R72615A will report data regularly according to MaxTime(default:720 min), and take about 

180

 seconds for the CO

2

 sensor to 

sample and process the collected CO

2

 value. The packets have temperature, humidity, CO

2

 and battery voltage value. 

 

    Note: Max Time can be modified by the downlink command, and recommended not to set the time too short to avoid   

battery power consumption. 

 

6.

 

R72615A is suitable for the following scenarios: 

 

Farm 

 

Pig farm 

 

Environmental monitoring 

 

 

 

 

 

 

 

 

 

 

Housing screw 

Screws Fixed 

Battery Pack 

DC in 

Содержание R72615A

Страница 1: ...echnology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence and shall not be disclosed to other par...

Страница 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 10 7 1 To determine whether a battery requires activation 10 7 2 How to activate the...

Страница 3: ...mmunication methods LoRa spread spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communic...

Страница 4: ...le with LoRaWAN 7 2V battery power supply Simple operation and setting CO2 and temperature and humidity detection Adopt SX1276 wireless communication module Temperature and Humidity Sensor CO2 Sensor...

Страница 5: ...o factory setting Turn off The green indicator flashes for 20 times success The green indicator remains off fail Press once The device is in the network The green indicator flashes once R72615A will s...

Страница 6: ...value if you were to manually trigger the device by pressing the button please be patient Note 1 The device report interval will be programmed base on the default firmware which may vary 2 The interva...

Страница 7: ...0PPM 0FA0 Hex 4000 Dec 4000 0 1PPM 400PPM 7th 8th byte FFFF NH3 data is not available 9th 10th byte FFFF Noise data is not available 11th byte 00 Reserved Packet 2 01090C4809C41B58FFFF00 1st byte 01 V...

Страница 8: ...0000000000000000 the configuration is failed 2 Read the R72615A device configuration parameters Downlink 0209000000000000000000 Devices return 8209001E0E100000000000 device current configuration param...

Страница 9: ...s of the battery pack before installation and insert 8 ER14505 3 6V batteries into the battery compartment 4 sections on the front and 4 sections on the back side as shown in Figure 1 2 Figure 1 Batte...

Страница 10: ...ta regularly according to MaxTime default 720 min and take about 180 seconds for the CO2 sensor to sample and process the collected CO2 value The packets have temperature humidity CO2 and battery volt...

Страница 11: ...passivation may also lead to voltage delay when the batteries are put into operation and our devices may not work correctly in this situation As a result please make sure to source batteries from rel...

Страница 12: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: