Waterline Structure:

 

 

 

 

                                   

 

 

 

Water line: Up to 300m* 

Water contact alarm: Recommended at least 3cm line length and at least 2mm depth of water (as the installation example diagram) 

Alert: Instant report (within 10 seconds) 

 

*The length of the waterline has been set when shipping. If the length needs to change, it requires to send back to factory for resetting. 

 

 

Installation Suggestions and Examples 

 

 

Содержание R718WBA

Страница 1: ...718WBA User Manual Copyright Netvox Technology Co Ltd This document contains proprietary technical information which is the property of NETVOX Technology It shall be maintained in strict confidence an...

Страница 2: ...able of Content 1 Introduction 2 2 Appearance 2 3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 8 7 Information about Battery Passivation 11 8 Important Maintenance Instruction...

Страница 3: ...spectrum modulation technique greatly extend the communication distance It can be widely used in any use case that requires long distance and low data wireless communications For example automatic me...

Страница 4: ...pping spread spectrum Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to the third part...

Страница 5: ...Joining Never join the network Turn on the device to search the network The green indicator keeps on for 5 seconds success The green indicator remains off fail Had joined the network Not in the origi...

Страница 6: ...er between 1 65535 Can not be 0 Report per Min Interval Report per Max Interval After power on the device will immediately send a version packet report and a data report including the attribute The de...

Страница 7: ...1 Status 0x00_success Reserved 8Bytes Fixed 0x00 ReadConfigR eportReq 0x02 Reserved 9Bytes Fixed 0x00 ReadConfigR eportRsp 0x82 MinTime 2bytes Unit s MaxTime 2bytes Unit s BatteryChange 1byte Unit 0 1...

Страница 8: ...and performs data sampling according to MinTime Interval When it is sleeping it does not collect data Wakes up and collects data 3 6V Does not report Wakes up and collects data 3 6V Does not report Wa...

Страница 9: ...e interval another cycle of MinTime MaxTime calculation will start 6 Installation This product comes with waterproof function When using it the back of it can be adsorbed on the iron surface or the tw...

Страница 10: ...ine length and at least 2mm depth of water as the installation example diagram Alert Instant report within 10 seconds The length of the waterline has been set when shipping If the length needs to chan...

Страница 11: ...eakage monitoring The bottom of the cabin monitoring Archives Warehouse Any place is necessary to detect if there is a leakage or is sensitive to the leakage R718WBA Report Time Real time Within 10 se...

Страница 12: ...me or if the storage temperature is too high This lithium chloride layer prevents rapid self discharge caused by continuous reaction between lithium and thionyl chloride but battery passivation may al...

Страница 13: ...elt some plastic parts Do not store in excessive cold place Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not throw knock or shak...

Отзывы: