6. Data Report 

 

The device will immediately send a version packet report along with an uplink packet including liquid level status, battery voltage. 

The device sends data in the default configuration before any configuration is done. 

 

Default Setting: 

Maximum time: 15min 

Minimum time: 15min (Detect the current voltage value and liquid level status by default setting) 

BatteryVoltageChange: 0x01 (0.1V) 

 

R718VA detection status: 

The distance between liquid level and sensor reaches the threshold will report, and the threshold can adjust sensitivity 

The device will detect the status regularly at the MinTime interval.   

 

When the device detects liquid level, status = 1   

When the device does not detect liquid level, status = 0 

 

There are two conditions in which the device will report the status of the detected liquid and the battery voltage at MinTime interval: 

a. When the liquid level changes from where the device can detect to where the device cannot detect. (1

0 ) 

b. When the liquid level changes from where the device cannot detect to where the device can detect. (0

1) 

If none of the above conditions is met, the device will report at the MaxTime interval. 

 

For the analysis of the data command reported by the device, refer to the Netvox LoRaWAN Application Command document and 

http://www.netvox.com.cn:8888/page/index

. 

 

Note:   

The device send data cycle depends on real programming configuration according to the customer’s inquiry. 

The interval between two reports must be the minimum time. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание R718VA

Страница 1: ...Model R718VA Wireless Capacitive Proximity Sensor Wireless Capacitive Proximity Sensor R718VA User Manual...

Страница 2: ...3 5 Set up Instruction 4 6 Data Report 5 7 Application Scenario 8 8 Installation 8 8 1 Measured liquid medium viscosity 8 8 2 Requirements of container and Installation Instruction 9 8 3 Adjust sensit...

Страница 3: ...ss Technology LoRa is a wireless communication technology dedicated to long distance and low power consumption Compared with other communication methods LoRa spread spectrum modulation method greatly...

Страница 4: ...Configuration parameters can be configured via a third party software platform data can be read and alerts can be set via SMS text and email optional Applicable to third party platforms Actility Thing...

Страница 5: ...f fail Fail to join the network when the device is on First two mins wake up every 15 seconds to send request After two mins enter sleeping mode and wake up every 15 minutes to send request Note Sugge...

Страница 6: ...iquid level status 1 When the device does not detect liquid level status 0 There are two conditions in which the device will report the status of the detected liquid and the battery voltage at MinTime...

Страница 7: ...VoltageChange 0 1V MaxTime MaxTime Sleeping MinTime Sleeping MinTime Note MaxTime MinTime Data will only be report according to MaxTime MinTime duration regardless BatteryVoltageChange value Descripti...

Страница 8: ...recommend to set the MinTime Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matte...

Страница 9: ...n be adsorbed a ferromagnetic material object or the two ends can be fixed to the wall with screws should be purchased Note Do not install the device in a metal shielded box or other electrical equipm...

Страница 10: ...el probe is directly facing so as not to affect the detection 8 2 1 The first usage Insulation Materials container Containers made of non metallic materials with flat surface uniform thickness tight m...

Страница 11: ...gs and the needed tools for drilling holes 2 Open one hole in the high position and one in low position the hole diameter have to match the size of the rubber plug 3 Put the rubber plug into the holes...

Страница 12: ...container the sensor will still detect when the sensor approaches the wall of the container If you want to use the sensor on a container of this kind of material the installation method should follow...

Страница 13: ...ubber tube 8 3 Adjust sensitivity Open the back cover of the sensor head adjust the sensitivity knob with a small screwdriver rotate counterclockwise to increase the sensitivity and rotate clockwise t...

Страница 14: ...and electronic components Do not store the device under excessive heat condition High temperature can shorten the life of electronic devices destroy batteries and deform or melt some plastic parts Do...

Отзывы: