4.

 

Set up Instruction

 

On/Off 

 

Power on 

Insert batteries. (users may need a screwdriver to open) 

Turn on   

Press and hold the function key for 3 seconds till the green indicator flashes once.   

Turn off (Restore to factory setting)  Press and hold the function key for 5 seconds till green indicator flashes 20 times. 

Power off 

Remove Batteries.   

Note 

1.The device will be off after removing the battery and insert it again. 

2.It is suggested to wait for at least 10 seconds between turning the device on and off. 

3.At 1

st

 -5

th

 second after power on, the device will be in engineering test mode.   

Network Joining 

 

If the device has never joined the 

network 

Turn on the device, and it will search for the network to join. 

The green indicator light stays on for 5 seconds: joins the network successfully 

The green indicator light remains off: fail to join the network 

If the device has joined the network 

and it is not set to default 

Turn on the device, and it will search for the previous network to join. 

The green indicator light stays on for 5 seconds: joins the network successfully 

The green indicator light remains off: fail to join the network 

If the device fails to join the network   

(when the device is turned on) 

It is suggested to check the device verification information on the gateway or consult your 

platform server provider when the device fails to join the network. 

Function Key 

 

Press the function key and hold the 

pressing for 5 seconds 

The device will be set to default and turned off 

The green indicator light flashes 20 times: success 

The green indicator light remains off: fail 

Press the function key once   

The device is in the network: green indicator light flashes once and sends a report 

The device is not in the network: green indicator light remains off 

Sleeping Mode 

 

The device is turned on and in the 

network 

Sleep period: Min Interval. 

When the reportchange exceeds setting value or the state changes: send a data report according 

to Min Interval.   

Low Voltage Warning 

Low Voltage 

3.2V 

 

Содержание R718NL3 Series

Страница 1: ...Wireless Light Sensor and 3 Phase Current Meter Model R718NL3 Wireless Light Sensor and 3 Phase Current Meter R718NL3 User Manual...

Страница 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 12 7 1 To determine whether a battery requires activation 12 7 2 How to activate the...

Страница 3: ...th 3 x630A Clamp On CT Range 10A 630A 1 When the current of the device that is 75A or below is less than 100mA the current is reported as 0 When the current of the device that is above 75A is less tha...

Страница 4: ...gh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption a...

Страница 5: ...s not set to default Turn on the device and it will search for the previous network to join The green indicator light stays on for 5 seconds joins the network successfully The green indicator light re...

Страница 6: ...in Interval 0x0E10 3600s CurrentChange 0x0064 100 mA Subject to factory settings IlluminanceChange 0x0064 100 Lux Subject to factory settings Current and Illuminance Detection When the function key is...

Страница 7: ...Unit 1mA Current3 2Bytes Unit 1mA Mulitplier1 1Byte the real current1 should convert with Current Multiplier 0x02 Battery 1Byte unit 0 1V Mulitplier2 1Byte the real current2 should convert with Curre...

Страница 8: ...mdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes 1 Configure report parameters MinTime 1min MaxTime 1min CurrentChange 100mA IlluminanceChange 100Lux Downlink...

Страница 9: ...ge i e BatteryVoltageChange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and col...

Страница 10: ...me Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data vari...

Страница 11: ...s time If the current variation does not exceed the default value the data will be reported regularly according to MaxTime Press the Key of the device to start sampling data and report the data after...

Страница 12: ...ed to set the torque as 4kgf to ensure the device is impermeable Installation Diagram Screw Fixation Screw Fixation R718NL3 Wire to be detected Wire to be detected Wire to be detected Current Directio...

Страница 13: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: