background image

 

 

1.

 

Introduction   

The R718NL3 series is a Light Sensor and 3-Phase Current Meter device for Netvox ClassA type devices based on the 

LoRaWAN open protocol and is compatible with the LoRaWAN protocol.

 

R718NL3 series have different measuring range for 

different variety of CT. 

It is divided into: 

R718NL3

 Wireless Light Sensor and 3-Phase Current Meter with 3 x 50A Solid Core CT   

(Range:100mA-50A ,

 

Accuracy ±1% within 300mA~50A) 

R718NL37

 Wireless Light Sensor and 3-Phase Current Meter with 3 x 75A Clamp-On CT 

     

(Range: 100mA -75A ±1%, Accuracy ±1% within 300mA~50A) 

R718NL315

 Wireless Light Sensor and 3-Phase Current Meter with 3 x 150A Clamp-On CT

 

  (Range:1A-150A ±1%)

 

R718NL325

 Wireless Light Sensor and 3-Phase Current Meter with 3 x 250A Clamp-On CT

   

(Range:1A-250A ±1%) 

R718NL363

 Wireless Light Sensor and 3-Phase Current Meter with 3 x630A Clamp-On CT 

 

(Range:10A-630A ±1%) 

 

* When the current of the device that is 75A or below is less than 100mA, the current is reported as 0. 

     

When the current of the device that is above 75A is less than 1A, the current is reported as 0.   

 

LoRa Wireless Technology 

LoRa is a wireless communication technology famous for its long-distance transmission and low power consumption. Compared 

with other communication methods, LoRa spread spectrum modulation technique greatly extend the communication distance. It 

can be widely used in any use case that requires long-distance and low-data wireless communications. For example, automatic 

meter reading, building automation equipment, wireless security systems, industrial monitoring. It has features like small size, 

low power consumption, long transmission distance, strong anti-interference ability and so on. 

 

LoRaWAN 

LoRaWAN uses LoRa technology to define end-to-end standard specifications to ensure interoperability between devices and 

gateways from different manufacturers.   

Содержание R718NL3 Series

Страница 1: ...Wireless Light Sensor and 3 Phase Current Meter Model R718NL3 Wireless Light Sensor and 3 Phase Current Meter R718NL3 User Manual...

Страница 2: ...3 Main Features 3 4 Set up Instruction 4 5 Data Report 5 6 Installation 9 7 Information about Battery Passivation 12 7 1 To determine whether a battery requires activation 12 7 2 How to activate the...

Страница 3: ...th 3 x630A Clamp On CT Range 10A 630A 1 When the current of the device that is 75A or below is less than 100mA the current is reported as 0 When the current of the device that is above 75A is less tha...

Страница 4: ...gh third party software platforms data can be read and alarms can be set via SMS text and email optional Available third party platform Actility ThingPark TTN MyDevices Cayenne Low power consumption a...

Страница 5: ...s not set to default Turn on the device and it will search for the previous network to join The green indicator light stays on for 5 seconds joins the network successfully The green indicator light re...

Страница 6: ...in Interval 0x0E10 3600s CurrentChange 0x0064 100 mA Subject to factory settings IlluminanceChange 0x0064 100 Lux Subject to factory settings Current and Illuminance Detection When the function key is...

Страница 7: ...Unit 1mA Current3 2Bytes Unit 1mA Mulitplier1 1Byte the real current1 should convert with Current Multiplier 0x02 Battery 1Byte unit 0 1V Mulitplier2 1Byte the real current2 should convert with Curre...

Страница 8: ...mdID 1 byte DeviceType 1 byte Device Type of Device NetvoxPayLoadData var bytes Max 9bytes 1 Configure report parameters MinTime 1min MaxTime 1min CurrentChange 100mA IlluminanceChange 100Lux Downlink...

Страница 9: ...ge i e BatteryVoltageChange 0 1V MaxTime sleeping sleeping 0H 15th M 30th M 45th M 1H 1H 10th M 1H 25th M 1H 40th M 1H 55th M 2H 10th M Wakes up and collects data 3 6V Does not report Wakes up and col...

Страница 10: ...me Interval value too low If the MinTime Interval is too low the device wakes up frequently and the battery will be drained soon 4 Whenever the device sends a report no matter resulting from data vari...

Страница 11: ...s time If the current variation does not exceed the default value the data will be reported regularly according to MaxTime Press the Key of the device to start sampling data and report the data after...

Страница 12: ...ed to set the torque as 4kgf to ensure the device is impermeable Installation Diagram Screw Fixation Screw Fixation R718NL3 Wire to be detected Wire to be detected Wire to be detected Current Directio...

Страница 13: ...orage period is more than one month from the date of battery production all the batteries should be activated If encountering the situation of battery passivation users can activate the battery to eli...

Страница 14: ...elt some plastic parts Do not store the device in places that are too cold Otherwise when the temperature rises to normal temperature moisture will form inside which will destroy the board Do not thro...

Отзывы: