10
Notes:
(1)
The device only wakes up and performs data sampling according to MinTime Interval. When it is
sleeping, it does not collect data.
(2)
The data collected is compared with the last data reported. If the data change value is greater than
the ReportableChange value, the device reports according to MinTime interval.
If the data variation is not greater than the last data reported, the device reports according to
MaxTime interval.
(3)
We do not recommend to set the MinTime Interval value too low. If the MinTime Interval is too
low, the device wakes up frequently and the battery will be drained soon.
(4)
Whenever the device sends a report, no matter resulting from data variation, button pushed or
MaxTime interval, another cycle of MinTime/MaxTime calculation is started.