5
Sleeping Mode
The device is on and in the network
Sleeping period: Min Interval.
When the reportchange exceeds setting value or the state changes: send a
data report according to Min Interval.
Low Voltage Warning
Low Voltage
2.4V
5.
Data Report
The device will immediately send a version packet report and the attribute report data
The device sends data in the default configuration before any configuration is done.
Default setting:
MaxTime: Max Interval = 60 min = 3600s
MinTime: Min Interval = 60 min = 3600s
BatteryVoltageChange: 0x01 (0.1V)
ActiveThreshold: 0x0003 (Threshold range: 0x0003-0x00FF; 0x0003 is the most sensitive.)
Deactivetime: 0x05 (Deactive time Range: 0x01-0xFF)
ActiveThreshold:
Active Threshold = Critical value ÷ 9.8 ÷ 0.0625
*The gravitational acceleration at standard atmospheric pressure is 9.8 m/s
2
*The scale factor of the threshold is 62.5 mg
R313FB vibration alarm:
When the device detects a sudden movement or vibration, change of the quiescent state, the device
waits for DeactiveTime to enter the quiescent state
and the count times are incremented by one, and a
report of the number of vibrations is sent. Then, it restarts to prepare for the next detection. If the
vibration continues to occur during this process, the timing restarts until it enters the quiescent state.
The counting data will not be saved when the power is off. The device type, Active vibration threshold
and DeactiveTime can be changed through the command sent by the gateway.
Note:
The device report interval will be programmed based on the default firmware which may vary.
The interval between two reports must be the minimum time.
Please refer Netvox
LoRaWAN Application Command document
and
Netvox Lora Command Resolver
http://loraresolver.netvoxcloud.com:8888/page/index
to resolve uplink data.