16

TROUBLE SHOOTING GUIDE

BEFORE CALLING FOR SERVICE

This list includes common occurrences that are not the result of a defect in

workmanship or materials.

Problem

Possible Cause

Solution

The unit

doesn't work

No power supply

Connect to a power outlet and switch on

Water full indicator flashes

Drain water tank and reset your setting, or
replace the water tank to right place

Room temperature is under
5

or above 35

.

Self-protection is designed to protect the unit,
thus it can't work under such temperature

Timer function is active.

Deactivate Timer function.

Display shows “E2”

Humidity and Temp. Sensor failure ,Change
the sensor

The

dehumidify

function

doesn't work

or the unit

starts

up/shuts

down

frequently

Is the air filter clogged?

Clean the air filter

Is the door/window
open?

Close the door/window

Is the unit close to any heat
resource?

Remove the unit to a cool place

Is the intake duct or
discharge duct obstructed?

Remove the obstruction from the discharge
duct or intake duct.

Display shows “CL”

Normal status, it indicates Temp. <5

Display shows “CH”

Normal status, it indicates Temp. >35

Display shows “LO”

Normal status, it indicates Humidity <20%

Display shows “HI”

Normal status, it indicates Humidity >90%

Unit is noisy

Is the unit tilted or unsteady?

Place it on flat ground to achieve less
vibration.

Is the air filter clogged?

Clean the air filter

Содержание OL20-B270R

Страница 1: ...is manual carefully before use and keep it for further reference The dehumidifier removes excess moisture from the air creating a comfortable environment for your home and office Its compact design al...

Страница 2: ......

Страница 3: ...portant Safety Instructions 3 6 Specification 7 Appliance Overview 8 Installation and Storage 9 10 Operating Instructions 10 12 Water Drainage 12 14 Cleaning and Maintenance 14 15 Trouble Shooting Gui...

Страница 4: ...frigerant If refrigerant leaks and comes in contact with fire or heating part it will create harmful gas and there is risk of fire Read the USER MANUAL carefully before operation Further information i...

Страница 5: ...caped gas If a leak is detected immediately evacuate all persons from the store ventilate the room and contact the local fire department to advise them that a propane leak has occurred Do not let any...

Страница 6: ...outlet that is grounded Unplug the power cord when cleaning or when not in use Do not operate with wet hands Prevent water from spilling onto the unit Do not immerse or expose the unit to rain moistu...

Страница 7: ...ell ventilated area where the room size corresponds to the room area as specified for operation WARNING Any person who is involved with working on or breaking into a refrigerant circuit should hold a...

Страница 8: ...efrigeration equipment or any associated parts appropriate fire extinguishing equipment shall be available to hand Have a dry powder orCO2 fire extinguisher adjacent to the charging area 2 2 6 No igni...

Страница 9: ...alled in a position where they are unlikely to be exposed to any substance which may corrode refrigerant containing components unless the components are constructed of materials which are inherently r...

Страница 10: ...put Current 2 0A 30 RH80 Water Tank Capacity 5 5L Sound Pressure Level 45dB A Refrigerant Charge R290 85 g Sound pressure level 45 dB A Product Dimension 335 238 594mm Net Weight 15 kg Maximum Suction...

Страница 11: ...8 APPLIANCE OVERVIEW Front panel Air outlet Castor Control panel Back panel Filter gridding Air inlet Handle Water tank...

Страница 12: ...iner such as bucket NOTE 1 Do not block the drainage port or water pipe 2 Do not fold the water pipe or make it 1 5m higher than the bottom of unit 3 Do not replace the rubber adaptor of the water pip...

Страница 13: ...direct sunlight extreme temperature and excessive dust OPERATION INSTRUCTIONS Instructions of indicator lights Power indicator After plugging in the power indicator will show green no matter the mach...

Страница 14: ...utton for 5 seconds then the fan running time resets to 0 Display It has 3 functions as below 1 When the power is on it shows the room humidity 2 When users adjust humidity it shows the set humidity d...

Страница 15: ...his button to switch low fan speed sleep or high fan speed turbo Mode button Press this button to choose normal mode or drying clothes mode WATER DRAINAGE I Water Tank When the water tank is full the...

Страница 16: ...will damage the water tank and lead to leakage 4 Please use two hands to put the water tank into the machine correctly or the water full indicator will still show red and the machine can not work IV C...

Страница 17: ...INTENANCE NOTE TURN OFF THE UNIT AND UNPLUG IT BEFORE ANY MAINTENANCE OR REPAIR TO AVOID ELECTRIC SHOCKS Cleaning Unplug the unit before any cleaning Do not sprinkle water on the unit Clean the housin...

Страница 18: ...ntly into warm water about 40 with a neutral detergent and rinse it then dry it thoroughly in a ventilated place Use the vacuum with its brush attachment to remove any dust 3 Assemble the filter Inser...

Страница 19: ...s E2 Humidity and Temp Sensor failure Change the sensor The dehumidify function doesn t work or the unit starts up shuts down frequently Is the air filter clogged Clean the air filter Is the door wind...

Страница 20: ...happens switch off the unit and unplug it immediately then contact a qualified electrician DISPOSAL INFORMATION Do not dispose of electrical appliances as unsorted municipal waste use separate collect...

Отзывы: