NV-202P Long Reach Ethernet Extender with PoE User’s Manual Ver. A4
23
Grounding the NV-202P
NV-202P is designed to enhance EMS performance by grounding. NV-202P comes with for grounding the switches. For optimal
EMS performance, connection of the left side of the NV-202P rear panel ground lug to the grounding point.
Before user installed power and device, please read and follow these essentials:
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must cross, make sure the
wires are perpendicular at the intersection point.
Note:
Do not run signal or communications wiring and power wiring through the same wire conduit. To avoid interference, wires with
different signal characteristics should be routed separately.
You can use the type of signal transmitted through a wire to determine which wires should be kept separate. The rule of thumb
is that wiring sharing similar electrical characteristics can be bundled together.
You should separate input wiring from output wiring.
We recommend that you mark all equipment in the wiring system.