16
5.6.3.
Logging by means of Dynamic Key Buffer to selected sector of
transponder
To complete logging successfully, it is important after any input of the reader, to reload
the Dynamic Key Buffer.
Command frame:
Header C_LoginWithDKB
SectorNo, KeyType, DKNo
CRC
Where:
Parameter name Parameter description
Value range
C_LoginWithDKB Logging to sector
0x18
SectorNo
Transponder sector number, to
which user wants to login.
0x00 – 0x0f (s50)
0x00 – 0x27 (s70)
KeyType
Key type, which is inside internal
Dynamic Key Buffer.
0xAA – key of A type
0xBB – key of B type
DKNo
Dynamic key number
0x00
Response frame:
Header C_LoginW1
OperationCode CRC
5.6.4.
Logging by means of Static Key Buffer to selected sector of
transponder
To complete logging successfully, it is important to load Static Key Buffer first.
Command frame:
Header C_LoginWithSKB
SectorNo, KeyType, SKNo
CRC
Where:
Parmeter name
Parameter description
Value range
C_LoginWithSKB Logging to sector
0x1a
SectorNo
Transponder sector number, to
which user wants to login.
0x00 – 0x0f (s50)
0x00 – 0x27 (s70)
KeyType
Key type, which is inside internal
Static Key Buffer.
0xAA – key of A type
0xBB – key of B type
SKNo
Static Key number
0x00…0x1F
Response frame:
Header C_LoginW1
OperationCode CRC