Configuration
23
Flex IO Inputs
Navigate to: Lock>Flex-IO Inputs
There are 4 Flex I/O inputs available on the ALK3701-IP. Each input can be
customized to perform one of seven functions.
These are:
RTX
-request to exit switch
Callpoint
Fire Alarm Input
- connect to a volts free set of n/o or n/c
relay contacts. When the fire alarm is
activated the controller can be configured
to unlock the door and notify devices on
the network or the alert.
Auxiliary Report
-sends an Auxiliary Report to PolicyServer
which can be configured to react upon receipt.
Door Monitor
- connects to a set of volts free relay contacts (n/o or n/c),
monitoring the status of the door (open or closed)
Door Override (lock)
- when activated, the controller will lock the door and ignore
any command received until the condition is reset.
Door Override (open) - when activated, the controller will unlock the door and
ignore any command received until the condition is reset.