Configuration
11
Monitoring The Door Status
If you are using a monitored magnetic lock or door strike it is possible to get an
indication of the physical status of the door via relay contacts in the lock
mechanism. These are normally presented as C, N/O and N/C.
This feature senses whether the door is open or closed and toggles the relay
contacts. The controller can then be configured in software to react to the status of
the door.
The door contacts are connected to the lock
controller via terminals I12 and 0V as illustrated
in Figure 3.3. The illustration shows the N/O
contacts connected to I12, this is for illustration
purposes only. The lock controller will support
both N/O and N/C; this feature is configured in
software.