LKG 610 

  

 

 

 

 

 

Netech Corporation 

110 Toledo St, Farmingdale, NY 11735,  

 

http://www.NetechCorp.us

 

http://www.PressureMeter.com

 

 

 

 

Returning the LKG 610 for Re-Calibration 

 

Products returned to Netech for repair or recalibration requires a RMA (Return 

Authorization Number) for speedy processing of the service required.  

 

To obtain a RMA number follow the link 

http://www.NetechCorp.us

 and fill in the required 

information, Email 

service@netechcorp.

us

 or call 800-547-6557 (US & Canada), 

International 631-531-0100.  

 

When shipping units to the factory enclose a copy of the RMA and the number should 

be on used as the reference in the shipping label. 

 

The shipment should be addressed to:- 

 

Attn: Service Department 

Netech Corporation 

110 Toledo St. 

Farmingdale , New York 11735.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание LKG 610

Страница 1: ...LKG 610 Netech Corporation 110 Toledo St Farmingdale NY 11735 http www NetechCorp us http www PressureMeter com LKG 610 Electrical Safety Analyzer With 10 ECG Connectors INSTRUCTION MANUAL...

Страница 2: ...pair and Recalibration 6 Models and Part Numbers 7 General Overview Introduction 8 Key Features 8 Specifications 9 Instrument Familiarity 10 Controls Indicators 11 Preparation for use 12 Operating Ins...

Страница 3: ...otice and without incurring any obligation Netech guarantees availability of service parts for 5 years after the manufacture of the unit is discontinued The warranty is void if you elect to have the u...

Страница 4: ...st procedures are found to meet those specifications when it was shipped from the factory Calibration LKG 610 is calibrated using standards traceable to National Institute of Standards and Technology...

Страница 5: ...return or refund Only products returned within 60 days from the date of original purchase are eligible for refund credit In order to receive a partial refund credit of a product purchase price on a s...

Страница 6: ...aging or handling Use the original carton and packaging material for shipment Returns for Refund Credit A Return Material Authorization RMA number must be obtained from our service or customer service...

Страница 7: ...p www PressureMeter com Models and Part Numbers Part Number Description 535 110 10 Lead Electrical Safety Analyzer 110 V 535 220 10 Lead Electrical Safety Analyzer 220 V Standard Accessories Part Numb...

Страница 8: ...ted and the unit of measure is indicated by an individual LED Either the AAMI ESI 1993 or the IEC 601 1 test load may be selected Resistance measurements are made using the included model 503 single c...

Страница 9: ...SD DEVICE CURRENT 0 to 19 99 Amps Accuracy 2 Full Scale 1 LSD Line Voltage 1 to 300 Volts Accuracy 2 1 Volt TEST RECEPTACLE Hospital Grade 110 VAC 15 Amp or 220 VAC 10 Amp The rocker polarity switch s...

Страница 10: ...User Manual LKG 610 10 Instrument Familiarity 2 15 1 14 12 13 11 10 9 3 4 5 6 7 8...

Страница 11: ...nnection to the test receptacle 7 Polarity Switch A three position switch to select the normal and reverse polarity of the test receptacle The center position shuts the power off to the test receptacl...

Страница 12: ...110 Volt devices only 2 PN 535 220 for 220 Volt devices only Before proceeding with any measurement become familiar with the measurements and the function selector switch CAUTION Make sure that the po...

Страница 13: ...ice Current in Amps 3 Earth Leakage Current Measurement Press the EARTH LKG key See Figure 2 The Earth Leakage Ground Leakage Current is measured through the ground conductor of the Device Under Test...

Страница 14: ...he Cord Resistance in milliohms Hammer pressure levels in excess of 20 PSI will cause damage t Figure 2 Block Diagram for Cord Resistance measurement and Case Leakage measurement external 5 Leads Leak...

Страница 15: ...CAUTION During Isolation leakage measurements the LKG 610 introduces line voltage into the patient leads Even though it is current limited to 1milliAmp it is potentially lethal 7 Case Leakage Current...

Страница 16: ...ASSIS When the CHS GND switch is momentarily pressed the connection will be open and the display will read zero A test lead other than the 503 may require adjustment with the zero adjustment control 3...

Страница 17: ...akage current measurement the AAMI LOAD is connected in front of the INPUT AMPLIFIER and the voltage developed across it from the leakage current is measured Current Source and Amplifier Resistance is...

Страница 18: ...first year warranty expires Netech will provide a second year warranty The warranty is void if the LKG 610 is serviced by anyone other than Netech or if the warranty seal is broken Calibration Servic...

Страница 19: ...ssing of the service required To obtain a RMA number follow the link http www NetechCorp us and fill in the required information Email service netechcorp us or call 800 547 6557 US Canada Internationa...

Страница 20: ...User Manual LKG 610 20 Appendix This section is intentionally left blank for future use...