1 System Requirements
Ensure that the following requirements are met before installing the disk array system.
Operating Environment
• 15 cm (6-inches) of space around the NR6-8 for proper ventilation
• ambient temperature of 5°C to 40°C (40°F to 104°F)
• ambient non-condensing relative humidity of 10% to 85%
• dust, smoke, and oil free environment
• no large magnetic fields, such as those generated by a high voltage power cables
and motors, etc.
• no direct sunlight
• a flat, stable surface capable of supporting the NR6-8
VT100 Terminal Settings
Refer to the following table for a summary of VT100 terminal settings required to com-
municate with the NR6-8. Refer to your system manual for instructions on setting up the
VT100 terminal settings.
Item
Required Setting
Connection
Serial Port (COM1 or COM2)
Protocol
RS232 (Asynchronous)
Cabling
Null Modem cable
Baud Rate
115200
Data Bits
8
Stop Bit
1
Parity
None