background image

Data Port Connection 

 

Supported Cables and Transceivers 

 

See the following table for the list of supported cables and transceivers. 

  

 

Supported 

 

 

Description 

 

Note 

 

 

 

 

 

 

 

Distance 

 

   

  

 

 

 

 

   

 

1m 

 

1G Direct Attach Cooper (DAC) cable 

 

SFP to SFP 

 

 

 

 

   

 

 

 

1G Active Optical Cable (AOC) 

 

SFP to SFP 

 

 

 

 

 

   

 

 

 

10G Direct Attach Cooper (DAC) cable 

 

SFP+ to SFP+ 

 

 

 

 

 

   

 

 

 

10G Active Optical Cable (AOC) 

 

SFP+ to SFP+ 

 

 

 

 

 

   

 

 

 

25G Direct Attach Cooper (DAC) cable 

 

SFP28 to SFP28 

 

 

 

 

 

   

 

 

 

25G Active Optical Cable (AOC) 

 

SFP28 to SFP28 

 

 

 

 

 

   

 

 

 

40G Direct Attach Copper (DAC) cable 

 

QSFP+ to QSFP+ 

 

 

 

 

 

   

 

 

 

40G DAC fan out cable (to 4 x 10G) 

 

QSFP+ to 4 SFP+ 

 

 

 

 

 

   

 

 

 

100G Direct Attach Cooper (DAC) cable 

 

QSFP28 to QSFP28 

 

 

 

 

 

   

 

 

 

100G Active Optical Cable (AOC) 

 

QSFP28 to QSFP28 

 

 

 

 

   

 

3m 

 

1G Direct Attach Cooper (DAC) cable 

 

SFP to SFP 

 

 

 

 

   

 

 

 

1G Active Optical Cable (AOC) 

 

SFP to SFP 

 

 

 

 

 

   

 

 

 

10G Direct Attach Cooper (DAC) cable 

 

SFP+ to SFP+ 

 

 

 

 

 

   

 

 

 

10G Active Optical Cable (AOC) 

 

SFP+ to SFP+ 

 

 

 

 

 

   

 

 

 

25G Direct Attach Cooper (DAC) cable 

 

SFP28 to SFP28 

 

 

 

 

 

   

 

 

 

25G Active Optical Cable (AOC) 

 

SFP28 to SFP28 

 

 

 

 

 

   

 

 

 

40G Direct Attach Copper (DAC) cable 

 

QSFP+ to QSFP+ 

 

 

 

 

 

   

 

 

 

40G DAC fan out cable (to 4 x 10G) 

 

QSFP+ to 4 SFP+ 

 

 

 

 

 

   

 

 

 

100G Direct Attach Cooper (DAC) cable 

 

QSFP28 to QSFP28 

 

 

 

 

 

   

 

3m 

 

100G DAC fan out cable (to 4 x 25G) 

 

QSFP28 to SFP28 

 

 

 

 

 

   

 

 

 

100G Active Optical Cable (AOC) 

 

QSFP28 to QSFP28 

 

 

 

 

   

 

5m 

 

1G Direct Attach Cooper (DAC) cable 

 

SFP to SFP 

 

 

 

 

   

 

 

 

1G Active Optical Cable (AOC) 

 

SFP to SFP 

 

 

 

 

 

   

 

 

 

10G Direct Attach Cooper (DAC) cable 

 

SFP+ to SFP+ 

 

 

 

 

 

   

 

 

 

10G Active Optical Cable (AOC) 

 

SFP+ to SFP+ 

 

 

 

 

 

   

 

 

 

25G Direct Attach Cooper (DAC) cable 

 

SFP28 to SFP28 

 

 

 

 

 

   

 

 

 

25G Active Optical Cable (AOC) 

 

SFP28 to SFP28 

 

 

 

 

 

   

 

 

 

40G Direct Attach Copper (DAC) cable 

 

QSFP+ to QSFP+ 

 

 

 

 

 

   

 

 

 

40G DAC fan out cable (to 4 x 10G) 

 

QSFP+ to 4 SFP+ 

 

 

 

 

 

   

 

 

 

100G Direct Attach Cooper (DAC) cable 

 

QSFP28 to QSFP28 

 

 

 

 

 

   

 

 

 

100G Active Optical Cable (AOC) 

 

QSFP28 to QSFP28 

 

 

 

 

 

   

 

10m 

 

40G Active Optical Cable (AOC) 

 

QSFP+ to QSFP+ 

 

 

 

 

 

   

 

 

 

100G Active Optical Cable (AOC) 

 

QSFP28 to QSFP28 

 

 

 

 

 

 

   

 

 

 

 

17

 

Network Switch Installation Guide 

Содержание BES-53248

Страница 1: ...Broadcom supported BES 53248 Cluster Switch Installation Guide 215 14867_A0...

Страница 2: ......

Страница 3: ...ms and test equipment other than an ITE application may require further evaluation Safety Information Switch Safety Information To reduce the risk of body injury electrical shock fire and equipment da...

Страница 4: ...ned service technician The power cable extension cable or plug is damaged The equipment has been exposed to water The equipment has been dropped or damaged The equipment does not operate correctly whe...

Страница 5: ...at the total ampere rating of all products plugged into the extension cable or power strip does not exceed 80 of the ampere ratings limit for the extension cable or power strip To protect the equipmen...

Страница 6: ...the weight of the system Do not place additional load onto any rail mounted equipment System rack kits are intended to be installed in a rack by trained service technicians Site Selection The system...

Страница 7: ...aced before removing it from the switch Power Cord Warnings If an AC power cord was not provided with your product purchase one that is approved for use in your country CAUTION To avoid electrical sho...

Страница 8: ...t Warnings The following installation guidelines are required by UL for maintaining safety compliance when installing your switch into a rack The equipment rack must be anchored to an unmovable suppor...

Страница 9: ...ION Carefully route cables as directed to minimize airflow blockage and cooling problems For proper cooling and airflow operate the system only with the chassis covers installed Operating the system w...

Страница 10: ...ould void the user s authority to operate the equipment The customer is responsible for ensuring the compliance of the modified product Only peripherals computer input output devices terminals printer...

Страница 11: ...sed in a residential environment it may cause radio frequency disturbance Under such conditions users will be required to take certain appropriate countermeasures Network Switch 188 Units Hexavalent P...

Страница 12: ...tal server configuration is not to exceed the maximum loading conditions of the power supply Restriction of Hazardous Substances RoHS Compliance This product is manufactured by Quanta Computer Inc Qua...

Страница 13: ...ice is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired...

Страница 14: ...21 Hardware Installation 22 Unpacking the Hardware 22 Package Contents 22 Installing the Switch 22 Site Survey 22 Positioning the Switch 23 Rack Mounting the Switch 23 Connecting to the Console Port 3...

Страница 15: ...3 QSFP28 Port LEDs 7 PSU2 LED 14 QSFP28 Ports Rear panel No Item No Item 1 AC Power Connector with Plug 6 PSU2 Retainer 2 Earth Grounding M4 screw 7 Hot swappable Fan Modules 3 PSU Warning LED 8 Fan L...

Страница 16: ...mber Solid The system is booting Amber Blinking Equipment Event Green Solid The switch has loaded the agent software code and is operating normally Green Blinking The switch is loading the agent softw...

Страница 17: ...are abnormal Data Port LED State Description 25G SFP28 Port Speed LED number One per SFP28 port LED bi color amber Off No link green Amber Solid The port is linked at 25G speeds Amber Blinking The por...

Страница 18: ...GbE 8 QSFP28 ports 10 25 40 50 100GbE speed 1 Management port 1 Console port 1 USB port The chassis has 48 SFP28 and 8 QSFP28 ports Each of these ports uses an optical transceiver active optical cable...

Страница 19: ...ive Optical Cable AOC SFP to SFP 25G Direct Attach Cooper DAC cable SFP28 to SFP28 25G Active Optical Cable AOC SFP28 to SFP28 40G Direct Attach Copper DAC cable QSFP to QSFP 40G DAC fan out cable to...

Страница 20: ...orts The SFP28 ports support 10 25GbE IEEE 802 3by Ethernet for fiber mediums The SFP28 ports are numbered and have corresponding SFP28 port LEDs To install an SFP28 module do the following 1 Slide th...

Страница 21: ...module locks into place 3 Repeat the above procedures to install additional QSFP28 modules For more information about the QSFP28 port LED behavior when the network link is established refer to LED Ind...

Страница 22: ...e switch automatically adjusts its power setting to any supply voltage in the range from 100 240 VAC at 50 60 Hz NOTE Verify that each module has the same airflow direction Make sure the switch runs w...

Страница 23: ...the chassis and pushed toward the rear of the chassis The hot air exhausts through the vents on the rear panel of the switch Back to Front Airflow The air intake is located on the rear panel of the sw...

Страница 24: ...clean surface 3 Remove all other items from the box and inspect each item Installing the Switch Site Survey Consider the following when choosing a location to install the switch Installation Location...

Страница 25: ...ow To ensure proper airflow make sure that when you install the switch its air intake is positioned in a cold aisle and the air exhaust is positioned in a hot aisle for your data center NOTE Verify th...

Страница 26: ...from the middle rail Remove the inner rail NOTE Repeat the similar steps to remove another inner rail 2 Pull the tab upward to unlock the latch and then push the middle rail back into the outer rail...

Страница 27: ...h 7 Secure the rail mounting brackets with screws 8 Align the hooks on the switch with the holes in the inner rail and then slide the inner rail backward until it is locked in place 9 Secure the inner...

Страница 28: ...firmly into the rear rack until it clicks into place Make sure the L shaped bracket is facing inward 11 Pull the middle rail out until it is fully extended ensuring the ball bearing retainer is locke...

Страница 29: ...r with the inner rail 3 Secure the mounting ear with screws NOTE Repeat the similar steps to remove another inner rail and install the mounting ear 4 Install the outer rails to the rack To install the...

Страница 30: ...Network Switch Installation Guide 28...

Страница 31: ...witch with the screws Front Installation Rear Installation NOTE Repeat the similar steps to install another inner rail 7 Slide the inner rails on the switch into the middle rails and push the switch a...

Страница 32: ...J 45 male to RS 232 female cable for serial communication Below is the console cable wiring specification table RJ 45 Port of DB9 Female Port of Abbreviation Description Switch PC 3 2 RD Received Data...

Страница 33: ...operate in either half or full duplex and data rate can be in 10Mbps 100Mbps or 1Gbps Telnet SNMP and Web browser utility can all go through this port for local or remote management after the IP addre...

Страница 34: ...provide redundancy protection NOTE Each PSU has an AC power connector At least one power supply must connect to a power source To connect the switch to a power source do the following 1 Connect one en...

Страница 35: ...ssible issues Red state Fan Lock 15 sec OTP Over Temperature Process OCP Over Current Process OVP Over Voltage Process UVP Under Voltage Process Fan LED is in Red state One or more fans have failed Po...

Страница 36: ...upply removing the power supply will cause the switch to automatically shutdown The PSUs can be replaced without the use of special tools Before replacing any of the PSUs verify the status of the PSU...

Страница 37: ...assis NOTE Take note of the part number of the removed fan module When making order for replacement modules make sure that the part number of the new fan module is the same as the part number of the r...

Страница 38: ...AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLIGENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE EVEN IF ADVISED OF THE POSSIBILITY OF S...

Отзывы: