background image

 

z

Remove the blanking plate from the selected port.  

 

 

z

Carefully slide the faceplate of the UIM-2E1 under the lip of the MUM faceplate at the 

selected port opening such that the UIM-2E1 circuit board is facedown and the UIM-2E1 
label shows through the MUM port opening with the UIM-2E1 model name along the 
right-hand edge.  
 

z

Ensure that the mounting holes on the UIM-2E1 are lined up with the corresponding 
pems on the MUM circuit board and that the board-to-board connector key pins are 
properly aligned.  
 

z

Gently press down across the center of the UIM-2E1 circuit board until the board-to-
board connector is fully seated.  
 

z

Secure the UIM-2E1 circuit board to the MUM circuit board, at the pems, with the (4) 

provided panhead screws.  
 

z

Secure the UIM-2E1 faceplate to the MUM faceplate using the (2) provided beige 
flathead screws.  

 

 

1.3.1.2   Install the MUM in an IP DSLAM Chassis

 

The IPD12000 is a fourteen slot chassis; slots 1-12 are reserved for interface modules and 
slots 13-14 are reserved for multiplexer uplink modules (MUMs). The IPD4000 is a five slot 
chassis; slots 1-4 are reserved for interface modules and slot 5 is reserved for a MUM. 
 

z

Align the MUM with the slot module guides of the chosen slot for installation (either slot 
13 or 14 on the IPD12000 or slot 5 on the IPD4000).  
 

z

Slide the MUM firmly into the chassis. DO NOT USE EXCESS FORCE.  

 

z

Verify that the PWR (Power) LED on the MUM faceplate is illuminated.  
 

z

Tighten the fastening screws on the MUM faceplate.  

 

 

1.3.2   Mini DSLAM Installation

 

 

 

z

Remove the (8) beige flathead screws securing the Mini DSLAM chasis and carefully lift off the 
chassis cover. Set the screws aside.  
 

z

Select a port on the Mini DSLAM for UIM-2E1 installation: either port (1 or 2) may be used. 

Although not required for operational purposes, if redundancy is desired two UIMs may be 
installed on a Mini DSLAM, one in each port.  
 

z

Remove the blanking plate from the selected port.  

 
 

C

AUTION

Blanking plates should be stored for possible future use: if a UIM-2E1 is removed 
from a MUM, it must be replaced with either another UIM or a blanking plate. DO NOT 
OPERATE AN IP DSLAM 

WITH

 A MUM 

THAT 

HAS AN OPEN UIM PORT. 

C

AUTION

Disconnect all power sources from the Mini DSLAM before installing the UIM-2E1. 

220-0000083 rev 01