radio micro reed switch (rr3)

oPeRAtion

rr3 radio micro reed switches can be installed on 
windows and doors to detect opening. 

bAtteRy RePLAcement

carefully lift off the reed switch cover by unclipping 
at the bottom using a flat-bladed screwdriver or 
blunt knife. 
insert a new cr2032 3V lithium battery and then 
test the reed switch.
the new battery must be inserted in the battery clip 
with the positive (+) side up.

* example device 

number

universal transmitter (rr2) optional

oPeRAtion

universal transmitters can be used as window and 
door switches (same as radio reed switches) or as a 
universal transmitter for other devices as connected 
by your installer.
the rr2 also has an onboard vibration analyser with 
sensitivity adjustment. this allows optional nessen-
sor™ vibration sensors to provide wireless protection 
of door and window frames, works of art, jewellery 
cases, safes and other valuables.

bAtteRy RePLAcement

carefully lift off the universal transmitter cover by 
unclipping at the bottom using a flat-bladed screw-
driver or blunt knife. 
a warning sound will be heard when opening the 
case - this is normal. 
insert a new high capacity lithium 9V battery and 
then test the transmitter.

open here.

remove the 
cover.

* example device 

number

insert the new 
high energy 
lithium 9V 
battery.

lift battery 
out.

insert the new 
battery. cr2032 
3V lithium battery.

Positive (+) side up.

RR3

  

open here.

Содержание SecurityGuard III

Страница 1: ...Wireless Security System with GSM Monitoring Two Way Voice Owner s Manual SecurityGuard III With Two Way Voice Monitoring ...

Страница 2: ......

Страница 3: ...rgency over ride keyswitch GSM Dialler built in Congratulations on selecting SECURITYGUARD III to protect your family and home Your SECURITYGUARD III with its speak easy technology is a revolutionary radio based state of the art alarm system which has been built to the highest standards of industrial design and manufacturing The many sophisticated and innovative design features of the SECURITYGUAR...

Страница 4: ...rmed button Press once In these example house plans Armed areas are shown shaded Disarmed areas shown unshaded Valid Low Battery press User Code button Press once By Radio Key By Radio Keypad By Radio Key By Radio Keypad Valid Low Battery press User Code button Press twice Valid Low Battery press User Code By Radio Key By Radio Keypad button Press 3 times By Radio Key ...

Страница 5: ...and disarming Emergency Over ride Key Only to be used if your remote radio Keys are lost Insert key and turn anti clockwise to disable the SECURIT YGUARD III Store these keys in safe hidden place SECURITYGUARD III power off Turn the key anti clockwise SECURITYGUARD III power on Turn the key clockwise button Press once button Press hold for 4 seconds Valid Low Battery By Radio Key By Radio Keypad P...

Страница 6: ...ad RKP Operation RKP Radio Keypads have a full PIN pad for operat ing your SECURITYGUARD III using 3 to 6 digit user codes Your installer will set up and program the RKP to suit Buttons Used with your user code to arm the system Used with your user code to arm Home mode Enter button used when arming and disarming Press together Sounds the Panic alarm Not used Used by your installer only Lights Val...

Страница 7: ... enter The red light in the PIR will flash to indi cate that it has sensed your motion into the room If you don t see the red light you may not have waited long enough try again Leave the room Wait 5 minutes Red light indicates motion sensed Insert the new high energy Lithium 9V battery Unclip cover at the bottom Carefully lift off the sensor s cover by unclipping at the bottom using a flat bladed...

Страница 8: ...re Insert the new battery CR2477 3V Lithium battery Remove cover Positive side up Radio Door Bell RDB Operation Press the Door Bell button to sound the door chime at the SECURITYGUARD III main unit Battery Replacement Carefully lift off the RDB Door Bell unit s cover by unclipping at the bottom using a flat bladed screw driver or blunt knife Insert a new CR2032 3V Lithium battery and then test the...

Страница 9: ...sal transmitter for other devices as connected by your installer The RR2 also has an onboard vibration analyser with sensitivity adjustment This allows optional Nessen sor vibration sensors to provide wireless protection of door and window frames works of art jewellery cases safes and other valuables Battery Replacement Carefully lift off the Universal Transmitter cover by unclipping at the bottom...

Страница 10: ...supplied Alarm signals are delayed by 10 seconds before be ing sent to allow the on board sounder to be tested without triggering the alarm system Testing To test the sounder press and hold the Test button for at least 2 seconds If you hold the Test button for longer than 10 seconds it will also send an alarm signal to the SECURITYGUARD III Twist off NOTICE The RSM radio smoke detector is intended...

Страница 11: ...RITYGUARD III remotely from your mobile phone GSM monitoring needs an active mobile phone SIM card to operate Central station monitoring also requires a monitoring account with a moni toring company Wireless communication to central monitoring station via GSM Two Way Voice Your SECURITYGUARD III has Two Way Voice capabilities which means that in the event of an alarm you can listen in and talk bac...

Страница 12: ...32 3V Lithium battery Use only high energy Lithium 9V batteries Carbon or alkaline batteries are not recommended Photographs are used for illustrative purposes only Design and specifications may vary Made In Australia by Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and diligence has been applied during manufacture to ensure the reliable...

Отзывы: