secuRityguARd iii bAtteRy sPecificAtions

modeL

Battery

securityGuarD iii main unit

12V 3ah sealed lead acid (Gel) Battery

radio Key - 4 button

sealed housing, not user serviceable

radio Keypad

high energy lithium 9V battery*

r15 Pir motion sensor

high energy lithium 9V battery*

radio smoke Detector

high energy lithium 9V battery*

radio Panic Button

cr2477 3V lithium battery

rr3 radio reed switch

cr2032 3V lithium battery

rr2 universal transmitter

high energy lithium 9V battery*  

rDB radio Door Bell

cr2032 3V lithium battery

* use only high energy lithium 9V batteries. carbon or alkaline batteries are not recommended.

Photographs are used for illustrative purposes only. Design and specifications may vary.

made in australia by:

ness corporation manufacturing processes are accredited to iso9001 quality standards and all possible care and diligence has been applied during 
manufacture to ensure the reliable operation of this product. however there are various external factors that may impede or restrict the operation of this 
product in accordance with the product’s specification.
these factors include, but are not limited to:
1. erratic or reduced radio range. ness radio products are sophisticated low power devices, however the presence of in-band radio signals, high power 
transmissions or interference caused by electrical appliances such as wireless routers, cordless phones, computers, tVs and other electronic devices may 
reduce the range performance. While such occurrences are unusual, they are possible. in this case it may be necessary to either increase the physical 
separation between the ness receiver and other devices or if possible change the radio frequency or channel of the other devices.
2. unauthorised tampering, physical damage, electrical interruptions such as mains failure, electrical spikes or lightning.

Содержание SecurityGuard III

Страница 1: ...Wireless Security System with GSM Monitoring Two Way Voice Owner s Manual SecurityGuard III With Two Way Voice Monitoring ...

Страница 2: ......

Страница 3: ...rgency over ride keyswitch GSM Dialler built in Congratulations on selecting SECURITYGUARD III to protect your family and home Your SECURITYGUARD III with its speak easy technology is a revolutionary radio based state of the art alarm system which has been built to the highest standards of industrial design and manufacturing The many sophisticated and innovative design features of the SECURITYGUAR...

Страница 4: ...rmed button Press once In these example house plans Armed areas are shown shaded Disarmed areas shown unshaded Valid Low Battery press User Code button Press once By Radio Key By Radio Keypad By Radio Key By Radio Keypad Valid Low Battery press User Code button Press twice Valid Low Battery press User Code By Radio Key By Radio Keypad button Press 3 times By Radio Key ...

Страница 5: ...and disarming Emergency Over ride Key Only to be used if your remote radio Keys are lost Insert key and turn anti clockwise to disable the SECURIT YGUARD III Store these keys in safe hidden place SECURITYGUARD III power off Turn the key anti clockwise SECURITYGUARD III power on Turn the key clockwise button Press once button Press hold for 4 seconds Valid Low Battery By Radio Key By Radio Keypad P...

Страница 6: ...ad RKP Operation RKP Radio Keypads have a full PIN pad for operat ing your SECURITYGUARD III using 3 to 6 digit user codes Your installer will set up and program the RKP to suit Buttons Used with your user code to arm the system Used with your user code to arm Home mode Enter button used when arming and disarming Press together Sounds the Panic alarm Not used Used by your installer only Lights Val...

Страница 7: ... enter The red light in the PIR will flash to indi cate that it has sensed your motion into the room If you don t see the red light you may not have waited long enough try again Leave the room Wait 5 minutes Red light indicates motion sensed Insert the new high energy Lithium 9V battery Unclip cover at the bottom Carefully lift off the sensor s cover by unclipping at the bottom using a flat bladed...

Страница 8: ...re Insert the new battery CR2477 3V Lithium battery Remove cover Positive side up Radio Door Bell RDB Operation Press the Door Bell button to sound the door chime at the SECURITYGUARD III main unit Battery Replacement Carefully lift off the RDB Door Bell unit s cover by unclipping at the bottom using a flat bladed screw driver or blunt knife Insert a new CR2032 3V Lithium battery and then test the...

Страница 9: ...sal transmitter for other devices as connected by your installer The RR2 also has an onboard vibration analyser with sensitivity adjustment This allows optional Nessen sor vibration sensors to provide wireless protection of door and window frames works of art jewellery cases safes and other valuables Battery Replacement Carefully lift off the Universal Transmitter cover by unclipping at the bottom...

Страница 10: ...supplied Alarm signals are delayed by 10 seconds before be ing sent to allow the on board sounder to be tested without triggering the alarm system Testing To test the sounder press and hold the Test button for at least 2 seconds If you hold the Test button for longer than 10 seconds it will also send an alarm signal to the SECURITYGUARD III Twist off NOTICE The RSM radio smoke detector is intended...

Страница 11: ...RITYGUARD III remotely from your mobile phone GSM monitoring needs an active mobile phone SIM card to operate Central station monitoring also requires a monitoring account with a moni toring company Wireless communication to central monitoring station via GSM Two Way Voice Your SECURITYGUARD III has Two Way Voice capabilities which means that in the event of an alarm you can listen in and talk bac...

Страница 12: ...32 3V Lithium battery Use only high energy Lithium 9V batteries Carbon or alkaline batteries are not recommended Photographs are used for illustrative purposes only Design and specifications may vary Made In Australia by Ness Corporation manufacturing processes are accredited to ISO9001 quality standards and all possible care and diligence has been applied during manufacture to ensure the reliable...