9
To program the ReLAy OUTPUT to operate by a LOW BATTeRy signal from transmitters.
Relay oUtPUt oPeRatIon
1
O
n
2
3
4
5
Program Mode
ON/ALARM Pulses relay
PANIC/TAMPR Pulses relay
AUX Pulses relay
LOW BATT Pulses relay
Operating Mode
ON/OFF/ALRM
Latches relay
PANIC/TAMPR Toggles relay
AUX Toggles relay
LOW BATT Latches relay
1
O
n
2
3
4
5
Program Mode
ON/ALARM Pulses relay
PANIC/TAMPR Pulses relay
AUX Pulses relay
LOW BATT Pulses relay
Operating Mode
ON/OFF/ALRM
Latches relay
PANIC/TAMPR Toggles relay
AUX Toggles relay
LOW BATT Latches relay
SIgNAL TyPe
LOW BATT
ReLAy MODe
LATChINg
ReLAy ACTION
LOW BATT signal:
Latch On
SWITCh SeTTINgS
Switch 5 off, Switches
2, 3, 4 on
SIgNAL TyPe
LOW BATT
ReLAy MODe
PULSe
ReLAy ACTION
LOW BATT signal:
Pulse
SWITCh SeTTINgS
Switch 5 on, Switches
2, 3, 4 off
OPeRATION
OPeRATION
LOW BATT from any programmed device
> Relay Latches On
The relay will latch off when all devices
send a battery restoral signal
LOW BATT from any programmed device
> Relay Pulses 2sec
OPeRATION TABLe 7
OPeRATION TABLe 8
aCtIon
swItChes 2-5
InhIBIt InPUt
Relay
Radio Key or Reed Switch On/Off/Alarm
All Off
Input Ignored
Latch
Device Alarm, PIR or Reed Off/Restore
Switch 2 On
Input Ignored
No Change
Device Alarm, PIR or Reed On
Switch 2 On
Input Ignored
Pulse
Key ON
Switch 2 On
Low
No Change
Key ON
Switch 2 On
high
Pulse
Key OFF
Switch 2 On
Low
Pulse
Key OFF
Switch 2 On
high
No Change
taBle - Relay oPeRatIon wIth InhIBIt InPUt