11
+12V
0V
Input
AuX
nO
nC
C
RELA
Y
LOW
BAtt
pAnIC
tAMp
On/
ALARM
+12V
0V
Input
AuX
nO
nC
C
RELA
Y
LOW
BAtt
pAnIC
tAMp
On/
ALARM
ConneCtIon eXamPles
NeSS RADIO KeyS ARMINg/DISARMINg ANy CONTROL PANeL USINg INhIBIT INPUT
NeSS RK4 RADIO Key AUX BUTTON OPeRATINg A gARAge DOOR
Ness SCR+ Receiver
Ness SCR+ Receiver
To the keyswitch
input on the panel
From an output on
the control panel
which is high when
disarmed and low
when armed.
Requires an output from the control panel which is high when disarmed and
low when armed.
To garage door
controller input
AUX button
1
O
n
2
3
4
5
Program Mode
ON/ALARM Pulses relay
PANIC/TAMPR Pulses relay
AUX Pulses relay
LOW BATT Pulses relay
Operating Mode
ON/OFF/ALRM
Latches relay
PANIC/TAMPR Toggles relay
AUX Toggles relay
LOW BATT Latches relay
1
O
n
2
3
4
5
Program Mode
ON/ALARM Pulses relay
PANIC/TAMPR Pulses relay
AUX Pulses relay
LOW BATT Pulses relay
Operating Mode
ON/OFF/ALRM
Latches relay
PANIC/TAMPR Toggles relay
AUX Toggles relay
LOW BATT Latches relay
ON Button > Relay Pulses
2 sec when the Inhibit
Input is high
OFF Button > Relay
Pulses 2 sec when the
Inhibit Input is Low
12vDC supply
12vDC supply