18
Programming
Installation and Programming manual
The 8 available types/patterns, preset at default, are programmed
as indicated in the table:
Select a sounderflasher from the control panel layout (on the right
side of the page), then access the “Programming” section (on the
left side of the page) where you will find the following 5 sections:
REAL TIME
Press the “Real time” button to view the current values of the
following sounderflasher options:
•
Battery voltage
- internal battery voltage of the sounderflasher
•
Line voltage
- voltage measured of terminals 1 and 2
•
Temperature
- internal temperature value measured by the
heat gauge (
Table 3, J
)
•
Left/Right foam detector
- value detected by the foam-
tamper protection device (
Table 3, I
)
•
Tamper
- condition detected by the tamper protection sensor
(
Table 3, K
)
SOUNDER/
FLASHER
PARAMETERS
The “Read device” and “Write device” buttons will allow you to
download and set the device parameters listed in this section, which
coincide with those describe in paragraph
5-2 Programming Menu
.
Additionally, the device provides the “
IBUS monitor
” parameter
which, when activated after control panel reset, monitors the BUS
for one minute. The BUS status is indicated on the PRG LED:
•
On solid - BUS disconnected
•
1 blink per second - BUS connected and sounderflasher not
enrolled
•
2 blinks per second - BUS connected and sounderflasher enrolled
Table 9:
Pattern - default
n
Description
of pattern
Activate
sounder
Sounder
duration
(seconds)
Sound
type
Volume
Activate
flasher
Flasher
duration
(seconds)
Flash
mode
(flash/min)
Activate
STATUS LED
PRG LED
TAMPER
output
FAULT output
1
Burgulary
ON
180
Tone 1
16
ON
180
56
OFF
2
Low-
volume
burgulary
ON
180
Tone 1
6
ON
180
56
OFF
3
Fire
ON
180
Tone 3
16
ON
180
56
OFF
4
Tamper
ON
180
Tone 1
16
ON
180
36
OFF
5
Prealarm
ON
30
Tone 1
0
ON
30
36
OFF
6 Automation
ON
3
Tone 1
6
OFF
OFF
7
Squack
ON
1
Tone 5
0
ON
3
On solid
OFF
8
Chime
ON
3
Tone 4
0
ON
3
On solid
OFF
A Cut-off pattern can be:
Total cut off
OFF
ininfluent
OFF
ininfluent
OFF