16
Programming
Installation and Programming manual
•
0
- PRG LED
•
1
- Right LEDs on flasher circuit
•
2
- Left LEDs on flasher circuit
•
3
- STATUS LED
•
- LED Off
•
- LED On solid
•
- LED blinking
Instead (under the caption “Options”), the programmable settings
for each item, highlighted on a grey background (
) are the
options enabled at default.
The following section describes the menu options.
0 -
Exit without saving
; when you come to this option, wait 20
seconds for the device to exit the programming phase without
saving.
-
Sounderflasher address on BUS
; the following table shows
the correlation between the LED combinations and the soun-
derflasher address:
1 -
START input
; allows you to select the polarity of the START
input.
-
I-BUS Loss delay
; allows you to select the time (15 minutes
at default) which must pass before the loss of the I-BUS is
signaled.
2 -
STOP input
; allows you to select the polarity of the STOP
input.
-
BUS Loss
; allows you to select the type of signalling associa-
ted with the loss of the I-BUS.
3 -
Audible signalling
; allows you to select the type of sound
emitted by the horn.
4 -
Maximum audible-signal time
; allows you to select the
maximum time the horn will sound for, after which only other
types of signalling will continue until the Ivy unit restores to
standby.
5 -
Visual signals
; the first option allows blinking on the STATUS
and PRG LEDs activated by the LED input; the other options
allow you to select the visual signal on the flasher.
6 -
TAMPER and FAULT Outputs
; allows you to select the type of
contact (normally open or normally closed) of the outputs during
standby status.
7/8 -
START/LED Input Activation
; allows you to select the
signalling associated with the activation of this input.
9/14 -
Power failure; Open-casing tamper; Foam tamper,
Blow-torch tamper; Horn damage; Battery fault
; allows
you to select the signalling associated with the event.
15 -
Restore Default / Address
; if you select the option with "all
LEDs On solid", the current programming will restore to fac-
tory default settings. Selection of the BUS Address is achieved
by the summing the value corresponding to each LED On solid
(max. 10); restoral to default does not change the assigned
address.
Table 8:
LED combinations
Address
Address
Address
1
4
7
2
5
8
3
6
9
10
3
2
1
0
3
2
1
0
3
2
1
0