NESS - M1 Installation and Programming Manual
Page 40
AR1: Sel Prg
ReportCodesArea1
AR1 01:000=Sec
Dialer Delay Time
AR1 02:Code= 00
Alm Abort Code
Menu 09 - Area Reporting Codes
09-Area Reporting
Codes
Area Report Codes
Description of Option
Each of the eight (8) Areas has specific communicator reporting codes for events that only
occur within that area. Using the up/down arrow keys, select the appropriate area, then
press the right arrow key to begin starting with option 01.
Dialer Delay Time is an amount of time following an alarm during which the report may be
aborted if the area is disarmed by a valid user. An optional alarm abort code may be
programmed to report. Range is 000 to 255 seconds. Default is 000 (delay disabled).
Alarm Abort code is an optional code that may be reported when an alarm is aborted
during the Comm Abort Time window. Range is 00 to FF. Default is 00 (no report).
.
Cancel Window Time is the time following an alarm during which a cancel code will be
reported if the area is disarmed. Cancel is not the same as abort since the alarm has
already reported. Range is 00 to FF. Default is 00 (no report).
Alarm Cancel code is the code that will be reported if the area in alarm is disarmed within
the Cancel Window Time. Range is 00 to FF. Default is 00 (no report).
Close Automatic code will be reported anytime the area is armed automatically by a Rule
from the RP software programming. Refer to the Ness-RP Rules Programming
instructions. Range is 00 to FF. Default is 00 (no report).
Close Early code will be reported if the area is closed prior to a programmed Expected
Arm time. Refer to the Ness-RP Rules Programming instructions. Range is 00 to FF.
Default is 00 (no report).
Close Extended code will be reported if a programmed Expected Arm time is extended by
a valid user. Refer to the Ness-RP Rules Programming instructions. Range is 00 to FF.
Default is 00 (no report).
Fail to Close code will be reported if the area is not armed by a programmed Expected
Arm time. Refer to the Ness-RP Rules Programming instructions. Range is 00 to FF.
Default is 00 (no report).
Late to Close code will be reported if the area is armed after a programmed Expected Arm
time. Refer to the Ness-RP Rules Programming instructions. Range is 00 to FF. Default
is 00 (no report).
Keyswitch Close code will be reported in place of a user code whenever the area is armed
by a keyswitch. Refer to the Ness-RP Rules Programming instructions. Range is 00 to
FF. Default is 00 (no report).
AR1 03:000=Sec
CancelWindowTime
AR1 04:Code= 00
Alm Cancel Code
AR1 05:Code= 00
Close Automatic
AR1 06:Code= 00
Close Early
AR1 07:Code= 00
Close Extended
AR1 08:Code= 00
Fail To Close
AR1 09:Code= 00
Late Close
AR1 10:Code= 00
Keyswitch Close
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
NOTE: Enter a two digit value to enable a particular report code. To disable a report code enter 00. When SIA or
Contact ID is the reporting format, the two digit value can simply be 01 since the control automatically produces the
correct code according to the SIA or Contact ID protocol. For 4+2 pulse format, enter a value from 01 to FF. To enter
the A thru F HEX characters press the RIGHT arrow key to position the cursor under the desired digit, then press the UP
arrow (shift) key once. Each press of the 2 key will now produce the following: 2, A, B, C. Each press of the 3 key will
now produce the following: 3, D, E, F. Press the RIGHT arrow key to cancel shift and move to the next character. See
Appendix for a summary of the SIA and Contact ID codes.
Содержание 101-201
Страница 1: ...Installation Manual M1 Cross Platform Control Specifications Installation and programming Rev 2 1 ...
Страница 5: ...NESS M1InstallationandProgrammingManual Page 5 General Communications Keypad options ...
Страница 48: ...NESS M1InstallationandProgrammingManual Page 48 Intentionally left blank ...
Страница 67: ...NESS M1InstallationandProgrammingManual Page 67 Intentionally left blank ...
Страница 72: ......