NESS - M1 Installation and Programming Manual
Page 33
CT01:=00600 sec
BurgDuration
CT02:=00000 sec
FireDuration
Menu 06 - Alarm Duration Timers
06-Alarm Cutoff
Timers
Alarm Cutoff Timers
Description of Option
Burglar Alarm duration time in seconds. Default time is 00600 sec. (10 min.). Burglar
always activates Siren/Voice Output (Out1) and Siren Output (Out2). Additional outputs
may be programmed using the RP software “Rules” function.
Fire Alarm duration time in seconds. Default time is 65535 sec. (never cutoff). Fire always
activates Siren/Voice Output (Out1) and Siren Output (Out2). Additional outputs may be
programmed using the RP software “Rules” function.
Medical Alarm duration time in seconds. Default time is 00600 sec. (10 min.). Medical
always activates Siren/Voice Output (Out1) and Siren Output (Out2). Additional outputs
may be programmed using the RP software “Rules” function.
Audible Police Alarm duration time in seconds. Default time is 00600 sec. (10 min).
Audible Police always activates Siren/Voice Output (Out1) and Siren Output (Out2).
Additional outputs may be programmed using the RP software “Rules” function.
CO (Carbon Monoxide) Alarm duration time in seconds. The default time is 00600 sec. (10
min.). This alarm type is not preassigned to any outputs. The RP software “Rules”
function must be used to assign outputs.
Emergency Alarm duration time in seconds. The default time is 00600 sec. (10 min.).
This alarm type is not preassigned to any outputs. The RP software “Rules” function must
be used to assign outputs.
Freeze Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
Gas Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This alarm
type is not preassigned to any outputs. The RP software “Rules” function must be used
to assign outputs.
Heat Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This alarm
type is not preassigned to any outputs. The RP software “Rules” function must be used
to assign outputs.
Water Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
Aux 1 Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
Aux 2 Alarm duration time in seconds. The default time is 00600 sec. (10 min.). This
alarm type is not preassigned to any outputs. The RP software “Rules” function must be
used to assign outputs.
CT03:=00600 sec
Med Duration
CT04:=00600 sec
Pol Duration
Each alarm type has a duration timer for cutting off the alarm after a programmable time period. Any output assigned to
the alarm type will turn on when the alarm activates and will turn off when the alarm cutoff timer expires. If multiple alarm
types are assigned to a single output, all alarms must turn off before the output can turn off. The range in seconds is
00000 to 65535. 00000=Never turn on. 65535=Never turn off NOTE: 65535 seconds is 1,092 minutes or 18.2 hours.
CT05:=00600 sec
CO Duration
CT06:=00600 sec
EmerDuration
CT07:=00600 sec
FrezDuration
CT08:=00600 sec
Gas Duration
CT09:=00600 sec
HeatDuration
CT10:=00600 sec
WatrDuration
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
CT11:=00600 sec
Aux1Duration
CT12:=00600 sec
Aux2Duration
Содержание 101-201
Страница 1: ...Installation Manual M1 Cross Platform Control Specifications Installation and programming Rev 2 1 ...
Страница 5: ...NESS M1InstallationandProgrammingManual Page 5 General Communications Keypad options ...
Страница 48: ...NESS M1InstallationandProgrammingManual Page 48 Intentionally left blank ...
Страница 67: ...NESS M1InstallationandProgrammingManual Page 67 Intentionally left blank ...
Страница 72: ......