![Ness 101-201 Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/ness/101-201/101-201_installation-manual_1669234030.webp)
NESS - M1 Installation and Programming Manual
Page 30
ZN001: Sel Prg
Zone 001
ZN001 01:Def=01
Burg Entry/Exit1
Menu 05 - Zone Definitions
05-Zone
Definitions
Zone Definitions
Description of Option
There are up to 208 zones. Press the UP or DOWN arrow key to scroll and select a
particular zone. To jump to any zone, enter the number from 001 to 208. The zone name
will display along the bottom line. Press the right arrow to program the selected zone.
This first option is used to set the zone definition. To locate a different option press the up
or down arrow key OR enter an option’s number to jump directly to it. Press the right
arrow key to program the selected option. The available definitions are:
00
Disabled
- Used to remove any unused zone(s). No need to put a jumper or resistor across the terminals.
01
Burglar Entry/Exit 1
- For perimeter entry/exit doors. Allows a time delay to enter and exit during arm and disarm.
02
Burglar Entry/Exit 2
- For perimeter entry/exit doors that require more time delay during arm and disarm.
03
Burglar Perimeter Instant
- Windows and perimeter openings. Activates an immediate Burglary alarm if tripped
during ANY armed mode. Does not provide any exit or entry delay.
04
Burglar Interior
- For motion detectors, interior doors, etc. Creates an instant alarm if tripped during the AWAY arm
mode. This zone type IS NOT ACTIVE during the STAY, STAY INSTANT, NITE, and NITE INSTANT arm modes.
05
Burglar Interior Follower
- For motions detectors, interior doors, etc. which may be in the keypad or entry pathway.
If an entry delay zone is violated first, this zone will delay (Follow) also, otherwise it will create an instant alarm.
This zone type IS NOT ACTIVE during the STAY, STAY INSTANT, NITE, and NITE INSTANT arm modes.
06
Burglar Interior Nite
- For motion detectors, interior doors, etc. which are not close to sleeping areas. The primary
use of this zone type is for increased security when the user is home. Interior Nite zones ARE ACTIVE during the
NITE and NITE INSTANT arm modes as well as the AWAY arm mode and will create an instant alarm if tripped.
This zone type is NOT ACTIVE during the STAY or STAY INSTANT arm modes.
07
Burglar Interior Nite Delay
- For motion detectors, interior doors, etc. that are not close to sleeping areas. Same
as an Interior Nite zone except that Interior Nite Delay zones will delay for the entry/exit delay 1 time period. Interior
Nite zones ARE ACTIVE during the NITE and NITE INSTANT arm modes providing increased security when the
user is home and in bed. However, if the user accidentally wanders into a Nite Delay zone the entry delay timer
will start and the tone will sound, warning the user to disarm before a false alarm occurs.
NOTE: If “Auto Stay,No Exit” is set to YES (see Area Definitions) and the system is armed in the Away
mode, all interior zones will be bypassed if no exit is detected from the premises during the exit delay time.
08
Burglar 24 hr
- Intended for tamper switches, etc. Activates an immediate Burglary alarm if tripped anytime
(during armed or disarmed state).
09
Burglar 24 hr Box Tamper
- Intended for control, siren, and bell box tamper switches. Activates an immediate
Burglary Tamper alarm if tripped anytime (armed or disarmed state).
10
Fire 24 hr Alarm
- Intended for Fire alarm sensors such as smoke detectors, heat stats, pull stations, etc.
Activates an immediate Fire alarm upon a short across the zone wires. A Fire Trouble will be activated if an open
(break in the zone wires) should occur.
11
Fire 24 hr ‘Verified’
- For smoke detectors in high-risk false alarm areas. Upon initial activation (short across the
zone), the control ignores the alarm and removes smoke power for 5 seconds to reset the detectors. During this 5
seconds, and for 25 additional seconds afterwards, no alarms will be recognized from this zone. Following this is
a 30 second verification time window, during which any additional activation will be regarded as verification of the
initial alarm and the control will initiate a Fire Alarm. If the 30 seconds expires with no further activations, the entire
process is cleared (reset). A Fire Trouble will be activated if an open (break in the zone wires) occurs.
12
Fire 24 hr Supervisory
- Intended for monitoring water control valves on fire sprinkler systems. Same as Fire 24hr
except that a short across the zone activates a Fire Supervisory alarm. A Fire Trouble will be activated if an open
(break in the zone wires) should occur.
13
Auxiliary1 24 hr
- This zone can trip anytime (armed or disarmed) and send a communicator report, but there is
no audible alarm output or keypad indication provided. It is displayed in the event log. A Whenever/And/Then rule
can be written from the RP software to do other things with this zone type. Resets upon restoral.
14
Auxiliary2 24 hr
- This zone can trip anytime (armed or disarmed) and send a communicator report, but there is
no audible alarm output or keypad indication provided. It is displayed in the event log. A Whenever/And/Then rule
can be written from the RP software to do other things with this zone type. Resets upon restoral.
Press RIGHT arrow key to select this menu. Press UP or DOWN arrow keys to select
another menu. The ELK key backs up one menu level. To exit press the * or Exit key.
Def Zone Description
Operating Characteristics
Away Stay Stay Instant Nite
Nite Instant
Burg Entry/Exit (1 or 2) Zone
A
A
AN
A
AN
QUICK VIEW OF ARMING MODES
Burg Perimeter (Instant) Zone
AN
AN
AN
AN
AN
This illustrates the condition of Burg
Burglar Burg Interior Zone
AN
-
-
-
-
zone types in the various arm modes.
Burg Interior Follower Zone
A
-
-
-
-
Legend: A = Armed
Burg Interior Nite Zone
AN
-
-
AN
AN
“-” = Not Armed,
Burg Interior Nite Delay Zone
AN
-
-
A
AN
AN = Armed, No Delay
Содержание 101-201
Страница 1: ...Installation Manual M1 Cross Platform Control Specifications Installation and programming Rev 2 1 ...
Страница 5: ...NESS M1InstallationandProgrammingManual Page 5 General Communications Keypad options ...
Страница 48: ...NESS M1InstallationandProgrammingManual Page 48 Intentionally left blank ...
Страница 67: ...NESS M1InstallationandProgrammingManual Page 67 Intentionally left blank ...
Страница 72: ......