![Nera saturn bp Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/nera/saturn-bp/saturn-bp_technical-manual_1668375039.webp)
37
Saturn Bp Portable – Technical Manual
S e r v i c e
S e r v i c e
S e r v i c e
List of Clear Causes
Ref No.
Display
Action
Comments
Message
Ref No.
Display
Action
Comments
Message
0000/000
UNSPECIFlED
REASON
1021/000
OFF_HOOK
TRY AGAIN
Off Hook was not received from addressed MES
TIMEOUT
terminal within time limit.
1081/000
TERMINAL ID
The specified MES terminal number has not been
MISMATCH
installed
1141/000
PRIORITY
PREEMPTION
Pre-emption by MES user instruction to establish a
higher priority call
1142/000
DISTRESS
PREEMPTION
Offered shore-call cleared, pre-empted at MES by
Distress.
1144/000
DISTRESS
Attempted ship-call cleared, pre-empted at MES by
PREEMPTION
Distress.
1145/000
PRIORITY
Attempted ship-call cleared, pre-empted at MES.
PREEMPTION
11D1/000 UNDEFINED
TRY AGAIN
Invalid information from MES; Service-Nature,
REASON
-Type or Channel Param.
11D2/000 INCORRECT
TRY AGAIN
The “service address” information received from
NUMBER
MES is invalid
11D3/000 INCORRECT
TRY AGAIN
The “service address” received from MES is currently
NUMBER
undefined
11D4/000 CREDIT CARD
TRY AGAIN
Credit card information received from the MES is
DATA INVALID
invalid
1201/000
SIMPLEX CALL
MES is acknowledging the receipt of a simplex call
SUCCESSFUL
1261/000
SIMPLEX CALL
Acknowledge of a simplex call which is possibly
UNSUCCESSFUL
unsuccessfully received.
1262/000
DISTRESS
Telephony ‘Distress Test’ call cleared after 120s
TEST TIMEOUT
12B1/001 DIAL TIMEOUT
TRY AGAIN
MES is clearing due to timeout of timer TS011
12B1/002 UNSUCCESSFUL TRY AGAIN
MES is clearing (no SCPC signal received)
CALL ATTEMPT
12B1/003 UNSUCCESSFUL TRY AGAIN
Channel is not tuned within allowed time limit.
CALL ATTEMPT
12B1/004 UNSUCCESSFUL TRY AGAIN
MES is clearing due to timeout. Waiting for assign-
CALL ATTEMPT
ment from NCS during shore call.
12B1/005 UNSUCCESSFUL TRY AGAIN
MES is clearing due to timeout. Waiting for assignment
CALL ATTEMPT
from NCS during distress call.
12B1/008 LES
TRY NEW LES
Signal NUMBER from user carries an illegal CES ac-
UNDEFINED
cess code parameter.
12B1/009 UNSPECIFIED
TRY AGAIN
Call rejected because a call set-up is already in
REASON
progress.
12B1/010 UNSUCCESSFUL TRY AGAIN
MES is clearing due to timeout. Waiting for assignment
CALL ATTEMPT
from NCS during ship call.
12B1/011 UNSUCCESSFUL TRY AGAIN
Respond-channel is not tuned in time.
CALL ATTEMPT
12B1/012 BUSY WITH
TRY LATER
Control did not grant access to terminal due to
CALL
conflicting ship call.
12B1/013 BUSY WITH
TRY LATER
Control did not grant access to terminal due to
CALL
conflicting shore call.
12B1/014 TOO FREQUENT
TRY LATER
Control did not grant access to terminal due to too
CALL ATTEMPT
frequents request.
12B1/015 MES BUSY
TRY LATER
Control did not grant access to terminal.
12B1/020 TEMPERATURE
System has failed. Ex. temperature alarm.
TOO HIGH
12B1/021 ANTENNA LINK
The communication link to ACU has failed.
FAILURE
12B1/022 TX BURST TIME
The tx burst duration has exceeded the maximum limit.
WAS TOO LONG
12B1/023 TX POWER OUT
The tx power output level has exceeded the maximum
WAS TOO HIGH
limit.
12B1/024 TX SYNTH.
TX synth out of lock, call cleared or abandoned.
FAILURE
12B1/025 INITIALIZING
System is not ready yet after start-up
TRY LATER
12B1/026 SPOT BEAM
Spot beam selection is being performed
SELECTION
12B1/027 NETWORK DATA
TRY LATER
Bulletin board data (satellite channel information etc.)
VALIDATION
is not yet verified
12B1/028 GROUP ID
Group IDs are being updated
DOWNLOAD
Содержание saturn bp