Activating and Reading the E-Coder)R900i
E-Coder)R900
i
Basement and Pit Installation and Maintenance Guide
7
Table 2 Icons and Displays
Solar Cell, located at the top of the E-Coder, supplies the power for the
register. It is activated by light.
Light Sensor, recessed under the small hole near the center of the face-
plate of the E-Coder)R900i, supplies the power for the LCD panel (light
activated).
Flow/Leak Indicator shows the direction of flow through the meter:
ON
Water in use
OFF
Water not in use.
Flashing
Water is running slowly/low flow indica-
tion.
Leak indicator displays a possible leak:
OFF
No leak indicated.
Flashing
Intermittent leak indicated. Water used
during at least 1/2 of the 15-minute inter-
vals in the last 24 hours (96 15-minute
intervals in a 24-hour period).
Continuous
ON
Continuous leak indicated. Water used
during all 15-minute intervals in the last 24
hours.
Nine-digit LCD displays the meter reading
in billing units of gallons or cubic feet.
Last
three
digits
Testing units used for meter testing.
Fifth & Sixth
reading
digits
Reading units.
First
four
digits
Typical billing digits.