HOW TO……..
Set Lock - Open-time
Press and Hold * for 2-
3 Sec’s until Red LED Flashes
<Enter>Admin Password #
34, 0#, Can set Open time to 50mS, pulse for some access control systems or RQE inputs. ##
34, (1-999) #, the default value is 2, set Open time from 1 to 999Sec
’
s **.
**Note: 999 Sec
’
s = 16 Mins
-
Exit Menu’s
## Note: Unlock-
time of Access Controller’s special power supply should set to min time to ensure the
actual Unlock-
time match with user’s
settings.
HOW TO……..
Set for Wiegand Reader
Press and Hold * for 2-
3 Sec’s
until Red LED Flashes
<Enter>Admin Password #
03 0# - Reader Mode
04 7# - Read EM, HID, IC cards (Default)
Note: This Model only supports EM/HID
64 4# - 1
–
5-digit key + # key buffered output (FC + 1-5 Digit PIN Code)
64 0# - 1
–
10 # key (1-10 Digit PIN Code)
60 xxx# - (0-255) Set facility code, not always required as Card/Tag FC is pass through.
-
Exit Menu’s
Wiegand Option - Wiring Diagrams -
NEPTUNE
Quick Reference Guide