15
- GB -
Storage/Over-wintering
•
Put the unit out of operation at water temperatures below 8 °C or, at the latest, when freezing temperatures are to
be expected.
•
Drain and thoroughly clean the unit, check for damage.
•
Remove, clean, dry and store all filters in a frost-free environment.
•
Ensure that the storage place is inaccessible to children.
•
Cover the filter container such that the ingress of rain water is excluded.
•
Drain all hoses, pipes and connections as far as possible.
Wear parts
The UVC lamp, the quartz glass and the filters are wear parts and are excluded from the warranty.
Disposal
Do not dispose of this unit with domestic waste! For disposal purposes, please use the return system provided.
Disable the unit beforehand by cutting off the cables.
Only dispose of the UVC lamp by using the return system provided for this purpose.
Remedy of faults
Malfunction
Cause
Remedy
Unit has been in operation only for a short time
The complete biological cleaning effect is only
achieved after several weeks
Water extremely soiled
Remove algae and leaves from the pond,
change the water
Excessive fish and animal population
Guide value: approx. 60 cm fish length in 1 m³3
pond water
Foam filters soiled
Clean filters
Quartz glass tube soiled
Remove UVC and clean quartz glass
The unit performance is not satisfactory
UVC lamp capacity exhausted
Replace the lamp after approx. 8,000 operating
hours
Power supply of Filtoclear-UVC not connected
Connect UVC power plug
UVC lamp defective
Replace the UVC lamp
Connection defective
Check electrical connection
UVC lamp display is not lit
UVC overheated
UVC automatically switches on when cooled
down
Pump power supply not connected
Connect pump power supply
Pond inlet blocked
Clean pond inlet
No water outlet from the pond inlet
Filter container/pump housing clogged
Clean filter container/pump housing
23583-01-14_GA_Druckfilter_NCTF-15 15
30.01.2014 13:34:10
Содержание Classic NCTF-O 5000
Страница 2: ...2 A PPS0011 B PPS0013 C PPS0014 23583 01 14_GA_Druckfilter_NCTF 2 2 30 01 2014 13 34 07 ...
Страница 3: ...3 D PPS0012 E PPS0015 23583 01 14_GA_Druckfilter_NCTF 3 3 30 01 2014 13 34 07 ...
Страница 4: ...4 F PPS0025 23583 01 14_GA_Druckfilter_NCTF 4 4 30 01 2014 13 34 09 ...
Страница 117: ...23583 01 14_GA_Druckfilter_NCTF 117 117 30 01 2014 13 34 15 ...
Страница 118: ...23583 01 14_GA_Druckfilter_NCTF 118 118 30 01 2014 13 34 15 ...
Страница 119: ...23583 01 14_GA_Druckfilter_NCTF 119 119 30 01 2014 13 34 15 ...